Glucose Monitoring by Direct Electron Transfer Needle-Type Miniaturized Electrode
نویسندگان
چکیده
منابع مشابه
Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a colloidal gold modified carbon paste electrode was investigated. The adsorbed GOD displayed a pair of redox peaks with a formal potential of -(449+/-1) mV in 0.1 M pH 5.0 phosphate buffer solution. The response showed a surface-controlled electrode process with an electron transfer rate constant of (38.9+/-5.3)/s determined in t...
متن کاملZnO-nanorods/graphene heterostructure: a direct electron transfer glucose biosensor
ZnO-nanorods/graphene heterostructure was synthesized by hydrothermal growth of ZnO nanorods on chemically reduced graphene (CRG) film. The hybrid structure was demonstrated as a biosensor, where direct electron transfer between glucose oxidase (GOD) and electrode was observed. The charge transfer was attributed to the ZnO nanorod wiring between the redox center of GOD and electrode, and the Zn...
متن کاملDirect Electron Transfer of Hemoglobin on Manganese III Oxide-Ag Nanofibers Modified Glassy Carbon Electrode
We investigated the electrochemical behavior of hemoglobin by glassy carbon electrode modified with Mn(2)O(3)-Ag nanofibers. The Mn(2)O(3)-Ag nanofibers were used as facilitator electron transfer between Hb and glassy-carbon-modified electrode. The Mn(2)O(3)-Ag nanofibers are studied by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The hemoglobin showed a quasir...
متن کاملCarbon Nanotubes Based Glucose Needle-type Biosensor
A novel needle-type biosensor based on carbon nanotubes is reported. Thebiosensor was prepared by packing a mixture of multi-wall carbon nanotubes (MWCNTs),graphite powder and glucose oxidase (Gox) freeze-dried powder into a glass capillary of 0.5mm inner diameter. The resulting amperometric biosensor was characterizedelectrochemically using amperometry in the presence of hydrogen peroxide and ...
متن کاملDirect electron transfer catalysed by enzymes: application for biosensor development.
The ability to catalyse an electrode reaction via direct (mediatorless) electron transfer has been demonstrated for a number of redox enzymes. In the case of mediatorless electron transfer, the electron is transferred directly from the electrode to the substrate molecule via the active site of the enzyme, or vice versa. The electron itself is the second substrate for the reaction. An important ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Electrochemistry
سال: 2012
ISSN: 1344-3542,2186-2451
DOI: 10.5796/electrochemistry.80.375