Gradient pre-emphasis to counteract first-order concomitant fields on asymmetric MRI gradient systems

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Deleterious Effect of Concomitant Gradient Fields on Diffusion Imaging

through-plane concomitant field phase accrual, for a phantom (squares no correction, triangles corrected) and human brain (circles no correction, diamonds corrected). Dephasing from concomitant gradient fields leads to error in ADC that increases with distance from isocenter (zS = 10cm-superior; zS = 0cm-inferior). FIG 1. Diffusion gradient timing for StejskalTanner (ST; insensitive to concomit...

متن کامل

Zero- to low-field MRI with averaging of concomitant gradient fields.

Magnetic resonance imaging (MRI) encounters fundamental limits in circumstances in which the static magnetic field is not sufficiently strong to truncate unwanted, so-called concomitant components of the gradient field. This limitation affects the attainable optimal image fidelity and resolution most prominently in low-field imaging. In this article, we introduce the use of pulsed magnetic-fiel...

متن کامل

Correction of concomitant gradient artifacts in experimental microtesla MRI.

Magnetic resonance imaging (MRI) suffers from artifacts caused by concomitant gradients when the product of the magnetic field gradient and the dimension of the sample becomes comparable to the static magnetic field. To investigate and correct for these artifacts at very low magnetic fields, we have acquired MR images of a 165-mm phantom in a 66-microT field using gradients up to 350 microT/m. ...

متن کامل

Efficient Second-Order Gradient Boosting for Conditional Random Fields

Conditional random fields (CRFs) are an important class of models for accurate structured prediction, but effective design of the feature functions is a major challenge when applying CRF models to real world data. Gradient boosting, which is used to automatically induce and select feature functions, is a natural candidate solution to the problem. However, it is non-trivial to derive gradient bo...

متن کامل

Efficient gradient calibration based on diffusion MRI

PURPOSE To propose a method for calibrating gradient systems and correcting gradient nonlinearities based on diffusion MRI measurements. METHODS The gradient scaling in x, y, and z were first offset by up to 5% from precalibrated values to simulate a poorly calibrated system. Diffusion MRI data were acquired in a phantom filled with cyclooctane, and corrections for gradient scaling errors and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2016

ISSN: 0740-3194

DOI: 10.1002/mrm.26315