Graphene–platinum nanocomposite as a sensitive and selective voltammetric sensor for trace level arsenic quantification
نویسندگان
چکیده
منابع مشابه
A Promising Enhanced Polymer Modified Voltammetric Sensor for the Quantification of Catechol and Phloroglucinol
In the present paper, poly(Tyrosine) modified graphene paste electrode (PTMGPE) was fabricated by utilizing an electropolymerization technique. Deposition of polymer film at bare graphene paste electrode (BGPE) was characterized by field emission scanning electron microscopy (FE-SEM). The PTMGPE was applied for Voltammetric detection of catechol (CC) and its quantification in phosphate buffer s...
متن کاملPoly(Niacin) Based Carbon Nanotube Sensor for the Sensitive and Selective Voltammetric Detection of Vanillin with Caffeine
In the current work, a novel sensor was developed for the analysis of Vanillin (VN) by electrochemical polymerization of Niacin over the surface of carbon nanotube paste electrode. The features of electrode surface was studied using Field Emission Scanning Electron Microscopy (FE‒SEM) images. Sweep rate variation study was conducted in the optimum pH (pH 7.0) for the evaluation of number of ele...
متن کاملFabrication of a Selective and Sensitive Electrochemical Sensor Modified with Magnetic Molecularly Imprinted Polymer for Amoxicillin
A modified electrochemical sensor for the determination of amoxicillin (AMX) was reported in this paper. The magnetic molecularly imprinted polymer (MMIP) were suspended in AMX solution and then collected on the surface of a magnetic carbon paste electrode (CPE) via a permanent magnet, situated within the carbon paste electrode and then the voltammetry signals were recorded. It was confirmed th...
متن کاملHighly selective and sensitive sensor based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane as a heterocyclic ionophore
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
متن کاملHigh-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Smart and Nano Materials
سال: 2014
ISSN: 1947-5411,1947-542X
DOI: 10.1080/19475411.2014.898710