Guidewire entrapment during Greenfield filter deployment

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

J-tip spring guidewire entrapment by an inferior vena cava filter.

The number of complications between guidewires and inferior vena cava filters is unknown and most likely underreported. Since 1993, at least 17 cases of central venous catheter guidewires entangled in inferior vena cava filters have been reported. The placement of both devices in the intensive care setting has increased the number of incidents in which a guidewire from a central venous catheter...

متن کامل

Troubleshooting for Ureteroscopy Complicated by Unexpected Guidewire Looping and Entrapment

This report presents a bizarre and unusual case of looping and entrapment of a hydrophilic guidewire in the ureter of a 65-year-old woman with a stone in the lower ureter at the time of ureteroscopy and laser lithotripsy. We describe endourology maneuvers to remove the retained guidewire. Looping and entrapment of guidewire is a rare complication that urologists may face when they do not follow...

متن کامل

Pulmonary embolism after insertion of a Greenfield filter.

This report describes a case in which a patient had a Greenfield filter placed at the time of diagnosis of deep vein thrombosis (DVT) when he was asymptomatic for pulmonary embolism. Later in the patient's hospital course, a typical clincal picture of pulmonary embolism developed. The issues examined in this report include: (1) the incidence of asymptomatic pulmonary embolism; (2) the value of ...

متن کامل

Braile Vena Cava Filter and Greenfield Filter in Terms of Centralization

The aim of this study was to evaluate complications experienced during implantation of the Braile Vena Cava filter (VCF) and the efficacy of the centralization mechanism of the filter. This retrospective cohort study evaluated all Braile Biomédica VCFs implanted from 2004 to 2009 in Hospital de Base Medicine School in São José do Rio Preto, Brazil. Of particular concern was the filter's symmetr...

متن کامل

[Rupture and intracoronary entrapment of an angioplasty guidewire with the X-Sizer thromboatherectomy catheter during rescue angioplasty].

The X-Sizer thromboatherectomy catheter represents an important advance for thrombectomy in thrombus-containing lesions, especially in patients who require primary and rescue angioplasty. Although it is safe, some complications have been reported as its use becomes more widespread. To our knowledge, the intracoronary breakage and retention of the angioplasty guidewire has not been reported. We ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Vascular Surgery

سال: 1998

ISSN: 0741-5214

DOI: 10.1016/s0741-5214(98)70305-2