Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hand-Held Dynamometry Isometric Torque Reference Values for Children and Adolescents

PURPOSE To establish hand-held dynamometry (HHD) maximal isometric muscle torque (MIT) reference values for children and adolescents who are developing typically. METHODS The MIT of 10 upper and lower limb muscle groups was assessed in 351 Caucasian youth (4 years 2 months to 17 years) using a standardized HHD protocol, previously shown to be feasible, valid, and reliable. RESULTS The mean ...

متن کامل

Hand-held myometry: reference values.

In thirteen major muscle groups of 50 healthy females and 50 males, aged 20-60 years, maximum voluntary contraction was measured with a hand-held dynamometer. The intrasession variation, the left-right variation, and the fifth and fiftieth centile values were calculated. The ratio of two observations within one session ranged from 0.85 to 1.18 and the ratio of left to right ranged from 0.82 to ...

متن کامل

Interrater reliability of hand-held dynamometry.

Two raters performed hand-held dynamometer testing of six muscle groups of 30 patients to determine the interrater reliability of the procedure. The six muscle groups tested were the shoulder external rotators, elbow flexors, wrist extensors, hip flexors, knee extensors, and ankle dorsiflexors. The patients were of eight different diagnostic groups, with most having hemiparesis secondary to cer...

متن کامل

Reliability of hand-held dynamometry in spinal muscular atrophy.

We have assessed the reliability of hand-held myometry in 33 patients with spinal muscular atrophy (SMA), testing elbow flexion, handgrip, three-point pinch, knee flexion, knee extension, and foot dorsiflexion, and determining intraclass correlation coefficients (ICC). Interrater reliability was high for upper limbs, with an ICC of 0.92 for three-point pinch and 0.98 for elbow flexion and grip....

متن کامل

Normative values for isometric muscle force measurements obtained with hand-held dynamometers.

BACKGROUND AND PURPOSE The extent of a patient's impairment can be established by comparing measurements of that patient's performance with normative values obtained from apparently unimpaired individuals. Only a few studies have described normative values for muscle strength measured by hand-held dynamometry. The purpose of this study of older adults, therefore, was to obtain normative values ...

متن کامل