Harmonic Distortion in Cochlear Models

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harmonic distortion in intracochlear pressure and its analysis to explore the cochlear amplifier.

Intracochlear pressure was measured close to the basal basilar membrane in gerbil with pure-tone stimulation. This report describes harmonic distortion in the pressure. The harmonic components were tuned in frequency and physiologically vulnerable, implying that they were related to the cell-derived force that sharpens tuning at low levels in healthy cochleae. For stimulus frequencies in the vi...

متن کامل

Harmonic Distortion and Adc

The influence of different ADC nonlinearities on the measurement of ADC intermodulation products is discussed. It is shown that the amplitudes of harmonics and intermodulation products can be predicted only if the low order nonlinearity of the transfer curve is dominant and if a sufficient level of input noise or dither is used. 1 INTRODUCTION The ADC nonlinearities produce persistent sine wave...

متن کامل

Harmonic distortion in microwave photonic filters.

We present a theoretical and experimental analysis of nonlinear microwave photonic filters. Far from the conventional condition of low modulation index commonly used to neglect high-order terms, we have analyzed the harmonic distortion involved in microwave photonic structures with periodic and non-periodic frequency responses. We show that it is possible to design microwave photonic filters wi...

متن کامل

Modelling the distortion produced by cochlear compression.

Lyon (J Acoust Soc Am 130:3893-3904, 2011) has described how a cascade of simple asymmetric resonators (CAR) can be used to simulate the filtering of the basilar membrane and how the gain of the resonators can be manipulated by a feedback network to simulate the fast-acting compression (FAC) characteristic of cochlear processing. When the compression is applied to complex tones, each pair of pr...

متن کامل

Errors Due to Harmonic Distortion and Noise

t AbstractLeast-squares' sine-fit algorithms are used extensively in signal-processing applications. The parameter estimates produced by such algorithms are subject to both random and systematic errors when the record of input samples consists of a fundamental sine wave corrupted by harmonic distortion or noise. The errors occur because, in general, such sine-fits will incorporate a portion of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of the Acoustical Society of America

سال: 1957

ISSN: 0001-4966

DOI: 10.1121/1.1918991