‘Harrier’ technique to close a penoscrotal incision following insertion of an inflatable penile prosthesis
نویسندگان
چکیده
منابع مشابه
The penoscrotal surgical approach for inflatable penile prosthesis placement
Optimizing outcomes with placement of inflatable penile prostheses (IPPs) can be challenging, especially in inexperienced hands. In this article, we outline Dr. Köhler's penoscrotal penile prosthesis surgical approach. We also highlight patient selection, post-operative care and complications.
متن کاملInflatable Penile Prosthesis Insertion in Men with Severe Intracorporal Fibrosis.
OBJECTIVES To retrospectively review a series of men who underwent attempted inflatable penile prosthesis (IPP) insertion into severely scarred corpora, and to analyze the surgical techniques and instruments that contributed to a successful outcome. PATIENTS AND METHODS All IPP procedures done by a high-volume prosthetic surgeon during a 5-year period were retrospectively reviewed. Fourteen p...
متن کاملErosion of an inflatable penile prosthesis due to autoinflation.
A 59-year-old man presented with erosion of an inflatable penile prosthesis. The cylinders were not deflated and the right one protruded from the urethra. Autoinflation that causes failure of deflation is an annoying and embarrassing mechanical failure. This failure may cause intraurethral erosion of the prosthesis. Urologists should inform their patients who hope for implantation of an inflata...
متن کاملDifference of opinion - Inflatable Penile Prosthesis - Opinion: Why I prefer the penoscrotal access.
The therapeutic arsenal of erectile dysfunction has in implant penile prostheses an option of third row, behind the phosphodiesterase-5 inhibitors and intracavernosal therapy. However, the satisfaction rate of treatment of erectile dysfunction with penile prostheses achieves excellent results, between 75 and 100% (1). The type of prosthesis to be implanted, inflatable or malleable, depends main...
متن کاملTubing Erosion of an Inflatable Penile Prosthesis Long after Implantation
INTRODUCTION Erosion through skin of connecting tubing of an inflatable penile prosthesis (IPP) has not been previously reported. AIM The aim of this study was to present a case of tubing erosion, review the pertinent literature, and discuss the possible causes and management options, including preservation of the device and its components. METHODS A 42-year-old male failing to respond to m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Annals of The Royal College of Surgeons of England
سال: 2017
ISSN: 0035-8843,1478-7083
DOI: 10.1308/rcsann.2017.0017