Heat transfer analysis of stationary bed materials in a CFB boiler after a sudden power failure
نویسندگان
چکیده
Compared to a pulverized coal boiler, circulating fluidized bed (CFB) boiler may face greater risk if sudden power failure accident happens due the massive materials in its main loop. In this study, numerical simulation is conducted analyze heat transfer process of stationary and estimate temperature based on real that happened 170 t/h CFB boiler. The results are consistent well with measurement data three measuring points, which indicates reliable. show continuously dissipate but cooling trends different areas different. average estimated reach 729.2 °C at end time simulation. It also found thermal conductivity material major influencing factor dissipation after failure, while effect emissivity slight.
منابع مشابه
a swot analysis of the english program of a bilingual school in iran
با توجه به جایگاه زبان انگلیسی به عنوان زبانی بین المللی و با در نظر گرفتن این واقعیت که دولت ها و مسئولان آموزش و پرورش در سراسر جهان در حال حاضر احساس نیاز به ایجاد موقعیتی برای کودکان جهت یاد گیری زبان انگلیسی درسنین پایین در مدارس دو زبانه می کنند، تحقیق حاضر با استفاده از مدل swot (قوت ها، ضعف ها، فرصتها و تهدیدها) سعی در ارزیابی مدرسه ای دو زبانه در ایران را دارد. جهت انجام این تحقیق در م...
15 صفحه اولanalysis of power in the network society
اندیشمندان و صاحب نظران علوم اجتماعی بر این باورند که مرحله تازه ای در تاریخ جوامع بشری اغاز شده است. ویژگیهای این جامعه نو را می توان پدیده هایی از جمله اقتصاد اطلاعاتی جهانی ، هندسه متغیر شبکه ای، فرهنگ مجاز واقعی ، توسعه حیرت انگیز فناوری های دیجیتال، خدمات پیوسته و نیز فشردگی زمان و مکان برشمرد. از سوی دیگر قدرت به عنوان موضوع اصلی علم سیاست جایگاه مهمی در روابط انسانی دارد، قدرت و بازتولید...
15 صفحه اولFailure Mode and Effect Analysis Power Plant Boiler
The current electricity demand is increasing, and now the government has involved third parties in the implementation of electricity so that investors compete in building infrastructure in order to apply electricity. Thermal power is one source that has a fast break event point compared to other resources that more interested investors even with all forms of pollution caused. A form of heat pow...
متن کاملFlow Analysis Heat and Mass Transfer in a Room
This reports the study on the flow behaviour, heat transfer and contamination distribution in a room. For this purpose the 3-D incompressible Navier-Stokes equations, energy equation and a mass transfer equation which model the concentration of contamination have been applied. For turbulence simulation the two equation standard k- turbulence model was employed. By means of SIMPLE algorithm the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fuel Processing Technology
سال: 2021
ISSN: ['1873-7188', '0378-3820']
DOI: https://doi.org/10.1016/j.fuproc.2020.106587