HIFU Drive System Miniaturization Using Harmonic Reduced Pulsewidth Modulation
نویسندگان
چکیده
منابع مشابه
HIFU beam localization using Harmonic Motion Imaging
Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of High-Intensity Focused Ultrasound (HIFU) surgery. However, accurate localization and characterization of the effective region of treatment (thermal lesion) remain the obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a novel HIFU ...
متن کاملPulsewidth Modulation Based on Real-Time Solution of Algebraic Harmonic Elimination Equations
Determination of pulse patterns for the elimination of some low-order harmonics of a PWM inverter necessitates to solve a system of nonlinear transcendental equations. When Newton’s algorithm is applied, it can be estimated that at each iteration, 2xN2 trigonometric functions have to be evaluated, N being the number of unknown switching angles in the first quarter-period interval. This is very ...
متن کاملPulsewidth Modulation for Electronic Power Conversion
The efficient and fast control of electric power forms part of the key technologies of modern automated production. It is performed using electronic power converters. The converters transfer energy from a source to a controlled process in a quantized fashion, using semiconductor switches which are turned on and off at fast repetition rates. The algorithms which generate the switching functions ...
متن کاملFree Vibration for an Electromagnetic Harmonic Movable Tooth Drive System
The authors proposed an electromagnetic harmonic movable tooth drive system which is an electromechanical coupled system where the coupled dynamics controls its overall operating behavior. However, the coupled dynamics of such a system was not found in the literature. In this paper, an electromechanical coupled dynamics equation of the flexible ring subjected to electromagnetic force is present...
متن کاملHigh intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI).
Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of high-intensity focused ultrasound (HIFU) treatment. However, accurate localization and characterization of the effective region of treatment (focal spot) remain important obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a HIFU mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
سال: 2018
ISSN: 0885-3010,1525-8955
DOI: 10.1109/tuffc.2018.2878464