We have built a high-accuracy wavelength meter for tunable lasers using a scanning Michelson interferometer and a reference laser of known wavelength. The reference laser is a frequency stabilized diode laser locked to an atomic transition in Rb. The wavemeter has a statistical error per measurement of 5 parts in 10 which can be reduced considerably by averaging. Using a second stabilized diode...
متن کاملScale-factor-stabilized fiber-optic gyroscope based on a spectrum-broadened laser-diode source.
A spectrum-broadened laser-diode source that uses the optical feedback and current-modulation effects has been adopted as the light source of a fiber-optic gyroscope to reduce the inherent phase noise. The scale factor of the gyroscope has also been stabilized.
متن کاملTreatment of lentigines by a novel high power diode laser at 755 nm: a case report
The use of high-power diode laser with a wavelength of 755 nm is an effective and safe method for the correction and partial and/or total elimination of pigmented lesions, specifically solar lentigines. This wavelength has yet not been used in diode lasers to treat solar lentigines. Side effects are the usual ones, including darkening and scab formation. Our patient was a 40-year-old woman of C...
متن کاملA COMPACT GRATING-STABILIZED DIODE LASER SYSTEM, AND A DOPPLER-FREE LASER POLARIZATION SPECTROMETER FOR Rb
We describe a compact, economic and versatile diode laser system based on commercial laser diode and a collimation tube, optically stabilized by means of feedback from a diffraction grating. Detailed instructions for the construction and operation of the diode laser system are presented. These instructions include machine drawings for the parts to be constructed. Our system offers single-mode o...
متن کاملUncertainty evaluation and electronic improvements of a wavemeter to measure the wavelength of an external cavity diode laser
A Michelson wavemeter was developed to test the accuracy and give traceability to the wavelength of external cavity diode lasers. These lasers were stabilized using a Littrow configuration and an iodine gas cell as frequency reference, and they were used as light sources in the assembly of a new interferometric system for the gauge block calibration. Previously, a microcontroller counting devic...