High Dose Rate CT Guided Brachyablation Versus High Dose Rate Stereotactic Ablative Radiotherapy for Lung Tumors
نویسندگان
چکیده
منابع مشابه
Safety of high-dose-rate stereotactic body radiotherapy
BACKGROUND AND PURPOSE Flattening filter free (FFF) beams with high dose rate are increasingly used for stereotactic body radiotherapy (SBRT), because they substantially shorten beam-on time. The physical properties of these beams together with potentially unknown radiobiological effects might affect patient safety. Therefore here we analyzed the clinical outcome of our patients. MATERIAL AND...
متن کاملCT - guided high dose rate brachytherapy ablation of liver metastases
383 ISSN 1755-5191 10.2217/IIM.13.41 © 2013 Future Medicine Ltd Imaging Med. (2013) 5(4), 383–388 Over the past two decades, several methods for minimally invasive tumor ablation have been developed and tested clinically. CT-guided high dose rate brachytherapy is an alternative radioablative technique that was introduced in clinical practice as a minimally treatment option almost 20 years ago w...
متن کاملQuality assurance prusedore in high dose rate bracythrapy
Introduction: Quality assurance is essential for obtaining the best achievable tumor control, avoiding unnecessary side effects, accuracy and safety during performing High Dose Rate (HDR) Brachytherapy (BT). Quality assurance is extremely important because HDR BT procedures are performed quickly, with high doses given in a short time period, with little opportunity for correcti...
متن کاملFractionated High-Dose-Rate Brachytherapy
Purpose: A growing body of data suggests that local control in nasopharyngeal cancer (NPC) is related to the radiation dose administered. We conducted a singleinstitution study of high-dose radiotherapy (RT), which incorporated high-dose-rate (HDR) brachytherapy (BT). These results were analyzed together with data obtained from controls who did not receive BT. Patients and Methods: The BT group...
متن کاملVaginal tolerance of CT based image-guided high-dose rate interstitial brachytherapy for gynecological malignancies
BACKGROUND Purpose of this study was to identify predictors of vaginal ulcer after CT based three-dimensional image-guided high-dose-rate interstitial brachytherapy (HDR-ISBT) for gynecologic malignancies. METHODS Records were reviewed for 44 female (14 with primary disease and 30 with recurrence) with gynecological malignancies treated with HDR-ISBT with or without external beam radiation th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Brachytherapy
سال: 2016
ISSN: 1538-4721
DOI: 10.1016/j.brachy.2016.04.295