منابع مشابه

A dwell position verification method for high dose rate brachytherapy

Misplacement of dwell positions is a potential source of misadministration in high dose rate brachytherapy. In this work we present a dwell position verification method using fluoroscopic images. A mobile C-arm fluoroscopic machine is used to take a snapshot of the treatment machine's check cable as it reaches the most distal dwell position. This fluoroscopic image is displayed side-by-side wit...

متن کامل

Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film

Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...

متن کامل

Dosimetric evaluation of multilumen intracavitary balloon applicator rotation in high‐dose‐rate brachytherapy for breast cancer

The objective of this work is to evaluate dosimetric impact of multilumen balloon applicator rotation in high-dose-rate (HDR) brachytherapy for breast cancer. Highly asymmetrical dose distribution was generated for patients A and B, depending upon applicator proximity to skin and rib. Both skin and rib spacing was ≤ 0.7 cm for A; only rib spacing was ≤ 0.7 cm for B. Thirty-five rotation scenari...

متن کامل

Independent assessment of source position for gynecological applicator in high-dose-rate brachytherapy

Purpose The aim of this study is to describe a phantom designed for independent examination of a source position in brachytherapy that is suitable for inclusion in an external auditing program. Material and methods We developed a phantom that has a special design and a simple mechanism, capable of firmly fixing a radiochromic film and tandem-ovoid applicators to assess discrepancies in source...

متن کامل

Intracavitary vaginal brachytherapy using a custom balloon applicator

A custom balloon applicator was created to deliver intracavitary high-dose-rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator. The custom applicator was constructed by inserting a straight titanium tandem applicator throug...