High-performance liquid chromatography of aflatoxins with fluorescence detection.
نویسندگان
چکیده
منابع مشابه
Determination of Astaxanthin in Trout by High Performance Liquid Chromatography Coupled with Visible Detection
Background: Astaxanthin is widely and naturally distributed in marine animals including, crustaceans, such as shrimp, crabs, and fish, such as salmon and trout. Methods: A total of 20 trout samples were collected from local market and were analyzed for astaxanthin via HPLC-UV. Analyte extraction was done by water, methanol, dichloromethane, and acetonitrile 4.5:85:5:45.5, v/v/v/v. Results: Desp...
متن کاملOccurrence of Aflatoxins in Peanuts and Peanut Products Determined by Liquid Chromatography with Fluorescence Detection
Liquid chromatography with fluorescence detection using immunoaffinity column clean-up was a method described for determination of aflatoxins (AFB1, AFB2, AFG1 and AFG2) in peanuts and peanut based products. The validation of the procedure was performed. Good coefficient of correlation was found for all aflatoxins in the range of 0.9993–0.9999. Limit of detection (LOD) and limit of quantificati...
متن کاملSimultaneous determination of furosemide and amiloride in plasma using high-performance liquid chromatography with fluorescence detection.
A high-performance liquid chromatographic method using fluorescence detection for the simultaneous determination of furosemide and amiloride is described. The chromatographic system is based on reversed-phase ion-pair chromatography with sodium dodecylsulphate as ion-pairing agent. The same counter-ion is used for the ion-pair liquid-liquid extraction to ethyl acetate. The minimum detectable co...
متن کاملDetermination of selenomethionine by high-performance liquid chromatography-fluorescence detection coupled with on-line oxidation.
A simple and sensitive determination method for selenomethionine (Se-Met) using an HPLC-fluorescence detection system coupled with an on-line electrochemical reactor has been developed. NBD-F (4-fluoro-7-nitro-2,1,3-benzoxadiazole) was used as the fluorescent derivatization reagent for Se-Met. NBD-Se-Met was separated from NBD-derivatives of 22 other amino acids within 35 min. Applying an optim...
متن کاملQuantification of Lipopeptides Using High-performance Liquid Chromatography with Fluorescence Detection after Derivatization.
A highly sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the determination of microbial lipopeptides of fluorescent derivatization with 1-bromoacetylpyrene to overcome the limitations of trace detection of lipopeptides in aqueous solutions. The derivatization of lipopeptides with 1-bromoacetylpyrene was conducted at 60°C for 20 min under cata...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Agricultural and Biological Chemistry
سال: 1978
ISSN: 0002-1369,1881-1280
DOI: 10.1271/bbb1961.42.2003