High pressure nucleation in water/nitrogen systems
Nucleation rate measurements of water in the presence of nitrogen as a carrier gas are reported at total pressures near 10, 25, and 40 bar, and temperatures of 230 and 250 K. The results were obtained using our pulse-expansion wave tube, particularly suited for high pressure nucleation research. Enhanced fugacity of water vapor in the mixture, due to the presence of nitrogen, was quantitatively...
متن کاملUnraveling the "pressure effect" in nucleation.
The influence of the pressure of a chemically inert carrier gas on the nucleation rate is one of the biggest puzzles in the research of gas-liquid nucleation. Experiments can show a positive effect, a negative effect, or no effect at all. The same experiment may show both trends for the same substance depending on temperature, or for different substances at the same temperature. We show how thi...
متن کاملCompetitive nucleation in metastable systems
Metastability is observed when a physical system is close to a first order phase transition. In this paper the metastable behavior of a two state reversible probabilistic cellular automaton with self–interaction is discussed. Depending on the self–interaction, competing metastable states arise and a behavior very similar to that of the three state Blume–Capel spin model is found.
متن کاملDesign of High Sensitivity and Linearity Microelectromechanical Systems Capacitive Tire Pressure Sensor using Stepped Membrane
This paper is focused on a novel design of stepped diaphragm for MEMS capacitive pressure sensor used in tire pressure monitoring system. The structure of sensor diaphragm plays a key role for determining the sensitivity of the sensor and the non-linearity of the output.First the structures of two capacitive pressure sensors with clamped square flatdiaphragms, with different thicknesses are inv...
متن کاملHigh Pressure Ammonia Systems – New Opportunities
Recent developments in the industrial refrigeration, air conditioning and heat pump sector have included significant increases in the typical operating pressures of systems. With ammonia this offers several opportunities to capitalise on the high critical temperature and high index of compression of the refrigerant in order to deliver heat efficiently in the temperature range 70C – 90C. It also...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Chemical Physics
سال: 1997
ISSN: 0021-9606,1089-7690