High-resolution geomagnetic observation system using HTS-SQUID

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution scanning SQUID microscope

We have combined a novel low temperature positioning mechanism with a single-chip miniature superconducting quantum interference device ~SQUID! magnetometer to form an extremely sensitive new magnetic microscope, with a demonstrated spatial resolution of ;10 mm. The design and operation of this scanning SQUID microscope will be described. The absolute calibration of this instrument with an idea...

متن کامل

High-Resolution Displacement Sensor Using SQUID Array Amplifier

We describe the design and operation principle of a new displacement sensor with a substantial improvement in resolution over what is currently possible. The potential for significant improvement in the measurement of displacement has profound implications for several high-impact gravitational physics and particle physics projects: the detection of gravitational waves, the test of the equivalen...

متن کامل

A Real-time High-resolution Underwater Ecological Observation Streaming System

This paper proposes a distributed architecture for real-time high-resolution underwater ecological observation streaming. The system, based on a three-tier architecture, includes stream receiver unit, stream processor unit, and presentation unit. It is a distributed computing and a loose coupling architecture. Stream receiver unit supports a variety of capture source devices, such as HDV, DV, W...

متن کامل

Design of Highly-sensitive Current Monitor with Hts Squid and Hts Magnetic Shield

A high-temperature superconducting (HTS) magnetic shield based on Bi(Pb)2-Sr2-Ca2-Cu3-Ox (Bi-2223) was fabricated by plasma spraying for the purpose of observing a somatosensory-evoked magnetic field generated from the human brain[1]. Recently, a Bi-2223 cylindrical magnetic shield was developed by dip-coating on a 99.9 % MgO ceramic substrate. A highly-sensitive current monitor using this HTS ...

متن کامل

HTS dc-SQUID flip-chip magnetometers and gradiometers

Biomagnetic research requires measuring systems with the utmost sensitivity to magnetic fields. The strongest challenge is fMEG measurements with a typical (20 – 200) fT peak-to-peak signal magnitude. An average R-wave magnitude of a fMCG signal is ∼2 pT. Measuring in a frequency bandwidth of about 100 Hz with a signal-to-noise ratio of ∼10 demands a system noise for fMCG measurements ∼20 fT/√H...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEICE Communications Express

سال: 2018

ISSN: 2187-0136

DOI: 10.1587/comex.2017xbl0168