High Resolution Laser Strainmeter
نویسندگان
چکیده
منابع مشابه
High Resolution Nonlinear Laser Spectroscopy
High resolution laser techniques were developed that address the problems listed above. The techniques are collectively called site selective laser spectroscopy. They relied upon the idea that a narrow band laser could be tuned to excite selectively an absorption line of a specific component or site within a sample so the resulting fluorescence spectrum came only from the site or component exci...
متن کاملHIGH RESOLUTION LASER SPECTROSCOPY IN COLD SUPERSONIC MOLECULAR BEAMS COOLING, REDUCTION OF DOPPLER WIDTH AND APPLICATION
The cooling of molecules during the adiabatic expansion of supersonic seeded molecular beams is reviewed and illustrated by the example of NO -molecules. The reduction of the Doppler width by collimation of the beam and the cooling to low rotational temperatures brings a significant simplification of the complex NO -absorption spectrum and allows its assignment. The measured rotational tem...
متن کاملPolarimetric high-resolution confocal scanning laser ophthalmoscope
A polarimetric high-resolution confocal scanning laser ophthalmoscope has been developed. The system incorporates a fixed linear polarizer in the illumination path and a rotatory quarter-wave plate and another fixed linear polarizer in the registration path. Retinal areas that are smaller than those provided by commercial instruments can be imaged. Series of four fundus images for independent p...
متن کاملLong range , high resolution laser radar
Initial laser radar experiments used CO* gas lasers at 10 pm [ I]. These lasers enabled either stable cw operation or high-gain pulsed output and have been used for wind measurements in the atmosphere. Despite the success of COz lasers, there has recently been an increased interest in the use of solid state, 1 urn laser technologies to be used for laser radar studies. The advantages of such a s...
متن کامل2 Searching for Small Deformation Signals in Laser Strainmeter Data Associated with Seismic Tremor in Parkfield
It has been hypothesized that shear dislocation on the plate interface accompanies deep tremor and low frequency earthquakes (LFE’s) (e.g. Wech and Creager, 2007; Ide et al, 2007; Shelly, 2007). We hope to test this claim on tremor and LFE’s on the San Andreas fault (SAF) through rigorous statistical examination of the laser strainmeter data from two long baseline instruments near Chalome, CA ....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature
سال: 1973
ISSN: 0028-0836,1476-4687
DOI: 10.1038/246470a0