High Time for High-Flux Hemodialysis Mechanistic Studies
نویسندگان
چکیده
منابع مشابه
high-flux and low-flux membranes: efficacy in hemodialysis
results the mean kt/v was 1.27 ± 0.28 in high-flux and 1.10 ± 0.32 in low-flux membrane which, these differences were statistically significant (p = 0.017). the mean of urr was 0.65 ± 0.09 in high-flux and 0.61 ± 0.14 in low-flux membrane, which these differences were not statistically significant (p = 0.221). patients and methods forty hemodialysis patients participated in this cross-over clin...
متن کاملLeukocyte Function in High-Flux Hemodialysis
Patients with chronic kidney disease and patients on renal replacement therapy, such as hemodialysis and peritoneal dialysis, have an increased susceptibility to infectious diseases compared with healthy subjects (Sarnak & Jaber 2000; Allon et al. 2003). Infection is also the second most common cause of morbidity and mortality in patients with end-stage renal disease (Bloembergen & Port 1996; P...
متن کاملVancomycin by High-Flux Hemodialysis Membranes
Levels of vancomycin in serum are traditionally believed to be unaffected by hemodialysis. By both in vivo and in vitro techniques, the effects of a newer, more permeable dialyzer membrane on vancomycin concentrations were investigated. Six patients who were receiving vancomycin and undergoing maintenance hemodialysis with polyacrylonitrile dialyzer membranes had postdialysis levels in serum th...
متن کاملHigh-Flux and Low-Flux Membranes in Hemodialysis
Background: Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that highflux membrane improves removal of moderatemolecules while other studies no significant on them. Objectives: The aim of this study was to investigate the dialysis adequacy of low-flux versus high-flux membranes in Hemodialysis Patients. Patients and Methods: Forty ...
متن کاملHigh-Flux and Low-Flux Membranes: Efficacy in Hemodialysis
BACKGROUND Inadequacy of dialysis is one of the main causes of death in hemodialysis patients. Some studies have suggested that high-flux membrane improves the removal of moderate-sized molecules while other studies indicate no significant effect on them. OBJECTIVES This study aimed to investigate the dialysis efficacy of low-flux versus high-flux membranes in hemodialysis patients. PATIENT...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Blood Purification
سال: 2008
ISSN: 0253-5068,1421-9735
DOI: 10.1159/000117439