Model-aided Diagnosis for High Voltage Circuit Breakers
ENGLISH) Motivated by economic pressures, power utilities are increasingly looking for new ways of reducing their costs while maintaining the quality of supply. A promising concept is predictive or condition based maintenance of high voltage equipment, based on continuos knowledge of each device’s condition. Power transformers and high voltage circuit breakers (HVCBs) have been the focus of att...
متن کاملTHESIS FOR THE DEGREE OF LICENTIATE OF ENGINEERING Controlled Switching of High Voltage SF6 Circuit Breakers for Fault Interruption
This thesis report describes an adaptive, self-checking algorithm for controlled short-circuit (fault) interruption in conjunction with high voltage alternating current SF6 circuitbreakers. The primary objective of controlled short-circuit interruption is to restrict the arcing time of the circuit-breaker to a nominal window (near the minimum arcing time) and thereby seek to reduce the electric...
متن کاملReliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants
Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...
متن کاملSolid-State Circuit Breakers For Medium Voltage
How can the large power needs of future electric ships for propulsion, radar, and weapons systems be met given the prohibitive size and weight of the required number of standard 60 Hz AC generators and transformers? A solution may lie in a rugged, efficient, and compact solid-state, 10-20 kV Medium Voltage DC (MVDC) circuit breaker (Figure 1). In this paper, Diversified Technologies, Inc. will ...
متن کاملCold-weather Application of Gas Mixture (sf6/n2, Sf6/cf4) Circuit Breakers: a Utility User’s Perspective
Very low temperatures stress a circuit breaker in a complex manner. Mixed-gas circuit breakers were developed for use at temperatures as low as -50C. These breakers utilize a gas mixture of SF6 and CF4 or SF6 and N2 to prevent condensation of the SF6 gas and have been type tested at -50C to ensure travel characteristics, operating times, and gas tightness are acceptably affected. Today’s mixed-...