OBJECTIVE We examined the hypothesis that higher cerebral oxygen saturation (rSO2) during RCP is correlated with urinary output. METHODS Between December 2002 and August 2006, 12 patients aged 3 to 61 days and weighing 2.6 to 3.4 kg underwent aortic arch repair with RCP. Urinary output and rSO2 were analyzed retrospectively. Data were assigned to either of 2 groups according to their correspo...
متن کاملContinuous monitoring of jugular bulb venous oxygen saturation for evaluation of cerebral perfusion during carotid endarterectomy.
In this study we examined whether continuous monitoring of jugular bulb venous oxygen saturation (SjO2) is applicable for the evaluation of cerebral hypoperfusion during carotid endarterectomy (CEA). The subjects were 25 patients who underwent elective CEA under general anaesthesia. After the carotid stump pressure (SP) was measured, SjO2 and the somatosensory evoked potentials (SEP) were monit...
متن کاملRegional cerebral oxygen saturation is a sensitive marker of cerebral hypoperfusion during orthotopic liver transplantation.
Neurological complications contribute significantly to morbidity and mortality of patients after orthotopic liver transplantation (OLT). One possible cause of postoperative neurological complications is cerebral ischemia during the surgical procedure. In this study, we investigated the relationship between intraoperative changes in regional cerebral oxygen saturation (rSo(2)) and postoperative ...
متن کاملUse of transcranial cerebral oximetry to monitor regional cerebral oxygen saturation during neuroendovascular procedures.
Using transcranial cerebral oximetry, we monitored 30 patients who underwent cerebral angiography by the femoral route. Transcranial cerebral oximetry is a noninvasive technique of regional cerebral oxygen saturation measurement that uses near-infrared spectroscopy to differentiate oxyhemoglobin from reduced hemoglobin. Needle puncture, catheterization, and contrast media injection produced no ...
متن کاملCerebral Oxygenation during Laparoscopic Surgery: Jugular Bulb versus Regional Cerebral Oxygen Saturation
PURPOSE We hypothesized that regional cerebral oxygen saturation (rSO2) could replace jugular bulb oxygen saturation (SjvO2) in the steep Trendelenburg position under pneumoperitoneum. Therefore, we evaluated the relationship between SjvO2 and rSO2 during laparoscopic surgery. MATERIALS AND METHODS After induction of anesthesia, mechanical ventilation was controlled to increase PaCO2 from 35 ...