Highly Crosslinked Polyethylene Does Not Reduce Aseptic Loosening in Cemented THA 10-year Findings of a Randomized Study

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

No adverse effects of submelt-annealed highly crosslinked polyethylene in cemented cups

BACKGROUND AND PURPOSE Highly crosslinked polyethylene (PE) is in standard use worldwide. Differences in the crosslinking procedure may affect the clinical performance. Experimenatal data from retrieved cups have shown free radicals and excessive wear of annealed highly crosslinked PE. We have previously reported low wear and good clinical performance after 6 years with this implant, and now re...

متن کامل

Wear of highly crosslinked polyethylene acetabular components

BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...

متن کامل

Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.

BACKGROUND Charnley low-friction torque total hip arthroplasty (THA) remains the gold standard in THA. The main cause for failure is wear of the socket. Highly crosslinked polyethylene (HXLPE) has been associated with reduced wear rates. Also, oxidized zirconium has shown in vitro reduced wear rates. However, to our knowledge, there are no data comparing oxidized zirconium femoral heads with me...

متن کامل

Revision for aseptic stem loosening using the cemented Charnley prosthesis. A review of 351 hips.

We reviewed 351 cemented revisions of femoral stems performed for aseptic loosening. At a mean of six years after the revision operation 72.1% of the patients were pain-free and 21.4% had only mild or occasional discomfort. The latest radiographs showed definite stem loosening in 10 (2.8%) and 20 hips (5.7%) had required rerevision, only nine (2.6%) of which were for mechanical failure of the s...

متن کامل

Does bone quality predict loosening of cemented total hip replacements?

We matched 78 patients with a loose cemented Charnley Elite Plus total hip replacement (THR) by age, gender, race, prosthesis and time from surgery with 49 patients with a well-fixed stable hip replacement, to determine if poor bone quality predisposes to loosening. Clinical, radiological, biomechanical and bone mineral density indicators of bone quality were assessed. Patients with loose repla...