Highly Sensitive THz Refractive Index Sensor Based on Folded Split-Ring Metamaterial Graphene Resonators

نویسندگان

چکیده

A highly sensitive absorption-based sensor based on folded split-ring metamaterial graphene resonators (FSRMGRs) is designed, and its biomedical application in terahertz (THz) spectrum investigated. The has a nearly perfect absorption, with spectral absorption coefficient of 99.75% at 4 THz an average Q-factor 13.76. resonance peak frequency to the refractive index (RI) test medium (analyte), fairly high sensitivity 851 GHz/RIU been obtained. specifications can be tuned by external DC-bias voltage applied layer. According obtained results, developed absorber appears good candidate bio-sensing applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional movable metamaterial using electric split-ring resonators.

We have demonstrated a three-dimensional movable metamaterial (MM) with reconfigurable electric split-ring resonators (eSRR) at terahertz frequencies. This is accomplished by making planar arrays of eSRR with movable stress curved beams (eSRR-MSCBs) which are actuated out-of-plane by electrostatic force. Our results have demonstrated that the eSRR-MSCBs possess blueshifting capabilities and pol...

متن کامل

Capacitor-loaded split ring resonators as tunable metamaterial components

Transmission through split ring resonator SRR structures loaded with capacitors is investigated both experimentally and numerically. Magnetic resonance frequency m is observed to shift to lower frequencies when capacitors are mounted to the various capacitive regions of the SRR structure. The amount of change in m depends strongly on the place where the capacitors are loaded. The magnetic reson...

متن کامل

Negative index of refraction in metallic metamaterial comprising split-ring resonators.

We numerically investigate the negative index of refraction in a metamaterial composed of metallic split-ring resonators, which exhibits simultaneously negative permittivity and permeability without resorting to additional metallic wires. It is confirmed that, in the left-handed band, negative permittivity is generated in analogy to the cut-wire metamaterial and negative permeability comes from...

متن کامل

A Highly Sensitive Fiber Optic Sensor Based on Two-Core Fiber for Refractive Index Measurement

A simple and compact fiber optic sensor based on a two-core fiber is demonstrated for high-performance measurements of refractive indices (RI) of liquids. In order to demonstrate the suitability of the proposed sensor to perform high-sensitivity sensing in a variety of applications, the sensor has been used to measure the RI of binary liquid mixtures. Such measurements can accurately determine ...

متن کامل

Highly sensitive refractive index sensor based on two cascaded microfiber knots with vernier effect

A highly sensitive refractive index (RI) sensor based on two cascaded microfiber knots with vernier effect is proposed and demonstrated by theoretical arithmetic. Deriving from high proportional evanescent field of microfiber and sharp spectrum fringes induced by vernier effect, a slight change of ambient RI will cause large variation of effective RI and significant wavelength shift of resonant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Plasmonics

سال: 2021

ISSN: ['1557-1955', '1557-1963']

DOI: https://doi.org/10.1007/s11468-021-01512-8