History and Systematic Review of Wear and Osteolysis Outcomes for First-generation Highly Crosslinked Polyethylene
نویسندگان
چکیده
منابع مشابه
Wear of highly crosslinked polyethylene acetabular components
BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...
متن کاملReview Article: Polyethylene wear and osteolysis in total hip arthroplasty.
Polyethylene wear has been accepted as a major cause of osteolysis in total hip arthroplasty. Submicron particles, which are secondary to abrasive wear, migrate into the effective joint space and stimulate a foreign-body response resulting in bone loss which is mainly mediated by macrophages. Diagnosis depends on serial radiographic evaluation and frequent follow-up. Polyethylene wear and osteo...
متن کاملthe innovation of a statistical model to estimate dependable rainfall (dr) and develop it for determination and classification of drought and wet years of iran
آب حاصل از بارش منبع تأمین نیازهای بی شمار جانداران به ویژه انسان است و هرگونه کاهش در کم و کیف آن مستقیماً حیات موجودات زنده را تحت تأثیر منفی قرار می دهد. نوسان سال به سال بارش از ویژگی های اساسی و بسیار مهم بارش های سالانه ایران محسوب می شود که آثار زیان بار آن در تمام عرصه های اقتصادی، اجتماعی و حتی سیاسی- امنیتی به نحوی منعکس می شود. چون میزان آب ناشی از بارش یکی از مولفه های اصلی برنامه ...
15 صفحه اولWear Reduction in Total Ankle Arthroplasty Using Highly Crosslinked UHMWPE
Introduction: Bearing couples within total ankle arthroplasty (TAA) typically utilize cobalt chromium alloys articulating on ultrahigh molecular weight polyethylene (UHMWPE). Articulation of these surfaces during in vivo loading can generate UHMWPE wear particles, which may then result in osteolysis and component loosening [1]. Osteolysis has been observed following TAA in 15-22% of patient pop...
متن کاملIn vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases.
This is the first report of in vivo wear particles from four total hip arthroplasties using remelted highly crosslinked polyethylene. The number of particles was (1.51 ± 0.45) × 10(7) g(-1) (mean ± standard error); particle size (equivalent circle diameter), 0.72 ± 0.15 µm; and roundness, 1.45 ± 0.05. Remelted highly crosslinked polyethylene generates fewer, rounder, equivalently sized particle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Orthopaedics & Related Research
سال: 2011
ISSN: 0009-921X
DOI: 10.1007/s11999-011-1872-4