[Effects of different reconstruction parameters on CT volumetric measurement of pulmonary nodules].

BACKGROUND AND OBJECTIVE It has been proven that volumetric measurements could detect subtle changes in small pulmonary nodules in serial CT scans, and thus may play an important role in the follow-up of indeterminate pulmonary nodules and in differentiating malignant nodules from benign nodules. The current study aims to evaluate the effects of different reconstruction parameters on the volume...

متن کامل

Small pulmonary nodules: volume measurement at chest CT--phantom study.

Three-dimensional methods for quantifying pulmonary nodule volume at computed tomography (CT) and the effect of imaging variables were studied by using a realistic phantom. Two fixed-threshold methods, a partial-volume method (PVM) and a variable method, were used to calculate volumes of 40 plastic nodules (largest dimension, <5 mm: 20 nodules with solid attenuation and 20 with ground-glass att...

متن کامل

Pulmonary nodules: volume repeatability at multidetector CT lung cancer screening.

PURPOSE To assess in vivo volumetric repeatability of an automated software algorithm in pulmonary nodules detected during a lung cancer screening trial. MATERIALS AND METHODS This study was approved by an institutional review board. Written informed consent was obtained from all participants. Data were collected from the Multicentric Italian Lung Detection project, a randomized controlled lu...

متن کامل

Solitary pulmonary nodules. CT-bronchoscopic correlation.

The possible contribution of computed tomography (CT) in the management of patients with solitary pulmonary nodules (SPNs) or masses was reviewed retrospectively in 65 patients undergoing fiberoptic bronchoscopy (FOB). Nodules were evaluated by size, location, surface contour, and the presence in cross-section of a bronchus leading to or contained within the nodule or mass, a "positive bronchus...

متن کامل

Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom study.

The purpose of this study is to investigate the effects of CT scanning and reconstruction parameters on automated segmentation and volumetric measurements of nodules in CT images. Phantom nodules of known sizes were used so that segmentation accuracy could be quantified in comparison to ground-truth volumes. Spherical nodules having 4.8, 9.5 and 16 mm diameters and 50 and 100 mg cc(-1) calcium ...