Human interface design using Button-type PEDOT electrode array in EIT
نویسندگان
چکیده
منابع مشابه
A compensated radiolucent electrode array for combined EIT and mammography.
Electrical impedance tomography (EIT), a non-invasive technique used to image the electrical conductivity and permittivity within a body from measurements taken on the body's surface, could be used as an indicator for breast cancer. Because of the low spatial resolution of EIT, combining it with other modalities may enhance its utility. X-ray mammography, the standard screening technique for br...
متن کاملDesign and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals
Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...
متن کاملDesign and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals
Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central compo...
متن کاملElectrode placement configurations for 3D EIT.
This paper investigates several configurations for placing electrodes on a 3D cylindrical medium to reconstruct 3D images using 16 electrode EIT equipment intended for use with a 2D adjacent drive protocol. Seven different electrode placement configurations are compared in terms of the following figures of merit: resolution, radial and vertical position error, image magnitude, immunity to noise...
متن کاملElectrode Placement Strategies for 3D EIT
We test strategies for placing EIT electrodes on a 3D medium for the purpose of calculating 3D reconstructions using clinical equipment intended for use with a 2D adjacent drive protocol. The goal of this work was to compare seven such strategies in order to determine if any were clearly superior to the others for clinical applications. For the limited set of strategies investigated, none were ...