Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human versus Computer Controlled Selection of Ventilator Settings: An Evaluation of Adaptive Support Ventilation and Mid-Frequency Ventilation

Background. There are modes of mechanical ventilation that can select ventilator settings with computer controlled algorithms (targeting schemes). Two examples are adaptive support ventilation (ASV) and mid-frequency ventilation (MFV). We studied how different clinician-chosen ventilator settings are from these computer algorithms under different scenarios. Methods. A survey of critical care cl...

متن کامل

Comparison of the effect of pressure support ventilation and volume assured pressure support ventilation on weaning patients off mechanical ventilation after cardiac surgery

Background: Weaning from mechanical ventilation in the intensive care unit is an important step in the treatment process. More patients in less than 6 hours after cardiac surgery can be separated from mechanical ventilation and extubated. However, 20-40% of patients after cardiac surgery, due to dysfunctional ventilator weaning response (DVWR), still remain under mechanical ventilation. Therefo...

متن کامل

Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...

متن کامل

Ventilator waveforms and the physiology of pressure support ventilation.

Pressure support ventilation (PSV) is a commonly used mode. It is patient-triggered, pressure-limited, and (normally) flow-cycled. Triggering difficulty occurring during PSV is usually due to intrinsic positive end-expiratory pressure. The airway pressure generated at the initiation of inhalation is determined by the pressure support setting and the pressure rise time (pressurization rate) sett...

متن کامل

A Case of Shunting Postoperative Patent Foramen Ovale Under Mechanical Ventilation Controlled by Different Ventilator Settings

A 56-year old male with ischemic heart disease and an unremarkable preoperative echocardiogram underwent surgical coronary revascularization. An intraoperative post pump trans-esophageal echocardiogram (TOE) performed while the patient was being ventilated at a positive end expiratory pressure (PEEP) of 8 cm H2O demonstrated a right to left interatrial shunt across a patent foramen ovale (PFO)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Critical Care Research and Practice

سال: 2012

ISSN: 2090-1305,2090-1313

DOI: 10.1155/2012/204314