Hybrid approach for aortic embolization of Amplatzer duct occluder
نویسندگان
چکیده
منابع مشابه
A new use for the amplatzer duct occluder device.
We report a case in which the Amplatzer device for percutaneous occlusion of ductus arteriosus was successfully used for occluding a large systemic-pulmonary collateral vessel in a patient who had previously undergone surgery for correction of pulmonary atresia and ventricular septal defect (Rastelli technique), and was awaiting the change of a cardiac tube. In the first attempt, the device emb...
متن کاملHybrid technique for ventricular septal defect closure in a dog using an Amplatzer® Duct Occluder II.
A left-to-right shunting muscular ventricular septal defect (VSD) was diagnosed in a 4-month-old, female, 1.8 kg Bichon Frise - poodle mix dog. Echocardiographic evidence of cardiac remodeling, calculated pulmonary blood flow (Qp) to systemic blood flow (Qs) ratio of 2.8, and radiographic evidence of pulmonary edema supported the diagnosis of a hemodynamically important VSD. Using a combination...
متن کامل[Intraoperative imaging of hybrid procedure for muscular ventricular septal defects closure with Amplatzer Duct Occluder II].
Hybrid approach becomes a promising conception of an alternative treatment for muscular ventricular septal defects (VSD) closure in infants. In this paper we report epicardial echocardiography imaging that enabled successful hybrid procedure performed in premature infant referred for surgical correction of a large perimembraneous VSD with simultaneous perventricular approach for concomitant mus...
متن کاملPercutaneous Forceps Retrieval of an Embolized Amplatzer Duct Occluder
Transcatheter closure of patent ductus arteriosus with the Amplatzer duct occluder shows excellent results. However, there is a risk of device embolization after deployment. We report the case of a 33-year-old man in whom an embolized Amplatzer device was retrieved from the right pulmonary artery by a percutaneous method. We also review this uncommon severe complication and offer technical tips...
متن کاملTranscatheter closure of aortopulmonary window with Amplatzer duct occluder II
Sir, An aortopulmonary window (APW) is a rare cardiac malformation, first reported by Elliotson, is found in 0.1% of patients with congenital cardiac lesions.[1] In most cases, surgical repair is undertaken during infancy although isolated cases have been reported of transcatheter device closures. We report our experience of transcatheter APW closure via antegrade and retrograde methods using a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Annals of Pediatric Cardiology
سال: 2020
ISSN: 0974-2069
DOI: 10.4103/apc.apc_13_20