Hybrid Optical Unobtrusive Blood Pressure Measurements
نویسندگان
چکیده
منابع مشابه
Hybrid Optical Unobtrusive Blood Pressure Measurements
Blood pressure (BP) is critical in diagnosing certain cardiovascular diseases such as hypertension. Some previous studies have proved that BP can be estimated by pulse transit time (PTT) calculated by a pair of photoplethysmography (PPG) signals at two body sites. Currently, contact PPG (cPPG) and imaging PPG (iPPG) are two feasible ways to obtain PPG signals. In this study, we proposed a hybri...
متن کاملDirect Blood Pressure Measurements
Intra-arterial pressure in the brachial artery was compared with that in the femoral artery in children. There were no significant differences in systolic, diastolic, or mean pressures. The average auscultatory systolic pressure in the arm, obtained with a cuff 20% wider than the limb, was identical to the average direct systolic pressure in the brachial and femoral arteries. The auscultatory s...
متن کاملSerial blood pressure measurements.
The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP) on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings wa...
متن کاملA Platform for Unobtrusive Measurements on PlanetLab
TCP Sidecar is a network measurement platform for injecting probes transparently into externally generated TCP streams. By coupling measurement probes with nonmeasurement traffic, we are able to obtain measurements behind NATs and firewalls without alerting intrusion detection systems. In this paper, we discuss Sidecar’s design and our deployment experience on PlanetLab. We present preliminary ...
متن کاملAutomatic Signal Appraisal for Unobtrusive ECG Measurements
This paper focuses on facilitating ECG-measurements in our daily life. When measuring ambulatory ECG, the trade-off between signal quality and sensor comfort is obvious. Unobtrusive measurement systems do not achieve the same level of signal quality as systems using conventional wet ECG electrodes. To enable automatic ECG analyses, a continuous appraisal of the signal quality is essential. The ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2017
ISSN: 1424-8220
DOI: 10.3390/s17071541