IMAGE FORMATION IN PANORAMIC TOMOGRAPHY
نویسندگان
چکیده
منابع مشابه
Image quality enhancement in digital panoramic radiograph
One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...
متن کاملEvaluation of the panoramic image formation in different anatomic positions.
The aim of this study was to determine size, shape and position of the image layer by evaluation of the radiographic image formation in different anatomic positions. A customized phantom was made of a rectangular acrylic plate measuring 14 cm² and 0.3 cm thick, with holes spaced 0.5 cm away and arranged in rows and columns. Each column was separately filled with 0.315 cm diameter metal spheres ...
متن کاملEvaluation of Image Magnification in Digital Panoramic Radiography
Introdouction: The aim of the present study was to investigate image magnification in digital panoramic radiography and assess the effect of anatomical sites on the magnification in both males and females. Materials and methods: In this retrospective study, digital panoramic radiographs of 48 patients with 202 implants were investigated. Implant diameter and length were measured on pan...
متن کاملPanoramic Image Stitching
Faculty of Computer Science by Kai Wang Pengbo Li Panoramic image stitching is an active research topic and lots of methods was developed to achieve a nice stitched panorama under different limitation of raw pictures. For example, pictures need to be aligned properly, pictures need to has same exposure level, or pictures need to be horizontal or vertical in space. In this project, we followed t...
متن کاملPanoramic Image Acquisition
This paper is concerned with acquirinig panoramic focused images using a small field of view video camera. When scene points are distributed over a range of disiances from the sensor, obtaining a f o c w e d composite image involves focus computations and mechanically changing some sensor parameters (translation of sensor plane, panning of camera etc.) which can be time intensive. In this paper...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1985
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003107047