Imaging of 99mTc-DMSA and 18F-FDG in humans using a Si/CdTe Compton camera

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

the diagnostic difference between 18f- fdg pet and 99mtc-hmpao spect perfusion imaging in assessment of alzheimer's disease

introduction:brain imaging with f-18 fluorodeoxyglucose (18f-fdg) positron ‎emission tomography or tc-99m hexamethylpropyleneamine oxime (‎99mtc-hmpao) spect is widely used for the evaluation of alzheimer's ‎dementia (ad); we aim to assess superiority of one method over the ‎other. methods: twenty four patients with clinical diagnosis of alzheimer disease ‎underwent 18f-fdg pet and ‎99mtc-...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

Evaluation of 99mTc-3PRGD2 integrin receptor imaging in hepatocellular carcinoma tumour-bearing mice: comparison with 18F-FDG metabolic imaging

OBJECTIVE Our study was designed to explore the utility of 99mTc-HYNIC-PEG4-E[PEG4-c(RGDfK)]2 (99mTc-3PRGD2) for the detection of hepatocellular carcinoma (HCC) and specifically to compare the diagnostic performance of 99mTc-3PRGD2 integrin receptor imaging and 2-18-fluoro-2-deoxy-D-glucose (18F-FDG) metabolic imaging in a nude mouse model. METHODS 99mTc-3PRGD2 was synthesized using a HYNIC-3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physics in Medicine & Biology

سال: 2020

ISSN: 1361-6560

DOI: 10.1088/1361-6560/ab33d8