Impact of Endoluminal Flow Diverter Number on Aneurysm Treatment Outcomes: A Multicenter Study
نویسندگان
چکیده
Background The purpose of this study is to evaluate the impact multiple overlapping flow‐diverting stents have on aneurysm occlusion rates and iatrogenic complications relative single stents. Methods A retrospective review a multicenter database from 2012 2020 was performed identify saccular aneurysms treated initially with ≥12‐month angiographic clinical follow‐up. Aneurysm as function stent number served primary outcome measure serving secondary measure. Results total 250 patients were Pipeline embolization device (PED), 48 PEDs. There no significant difference in size, morphology, or dual‐antiplatelet therapy regimen used between groups. (single, 83.6%, versus multiple, 83.4%; P =0.65) retreatment 8.0%, 10.4%; =0.58) procedure‐related groups 4.2%; =0.42), 0.8% PED 2.1% PEDs experiencing ischemic stroke. Conclusions overall nor are there differences complications. Single flow diversion may be preferred whenever possible, constructs reserved for extenuating circumstances encountered giant aneurysms.
منابع مشابه
Surpass flow diverter in the treatment of intracranial aneurysms: a prospective multicenter study.
BACKGROUND AND PURPOSE Incomplete occlusion and recanalization of large and wide-neck brain aneurysms treated by endovascular therapy remains a challenge. We present preliminary clinical and angiographic results of an experimentally optimized Surpass flow diverter for treatment of intracranial aneurysms in a prospective, multicenter, nonrandomized, single-arm study. MATERIALS AND METHODS At 2...
متن کاملThe ‘Sphere’: A Dedicated Bifurcation Aneurysm Flow-Diverter Device
We present flow-based results from the early stage design cycle, based on computational modeling, of a prototype flow-diverter device, known as the 'Sphere', intended to treat bifurcation aneurysms of the cerebral vasculature. The device is available in a range of diameters and geometries and is constructed from a single loop of NITINOL® wire. The 'Sphere' reduces aneurysm inflow by means of a ...
متن کاملa study on construction of iranian life tables: the case study of modified brass logit system
چکیده ندارد.
15 صفحه اولFlow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study.
BACKGROUND AND PURPOSE FD stent placement is a promising therapy for challenging intracranial aneurysms. Long-term evaluations about angiographic and morphologic results are still missing. This is the aim of this multicenter series. MATERIALS AND METHODS We report our experience and 1-year FU in a retrospective chart review of 65 consecutive subjects with 77 unruptured or recanalized aneurysm...
متن کاملInteraction between Flow Diverter and Parent Artery of Intracranial Aneurysm: A Computational Study
To evaluate the influence of deployment strategy on the mechanical interaction between braided stent and parent artery of intracranial aneurysm (the elasticity of the arterial wall is considered), finite-element analyses are carried out by referring to computational models of flow-diverter device and arterial wall. Two implantation strategies are used to virtually implant the braided stent into...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Stroke: vascular and interventional neurology
سال: 2022
ISSN: ['2694-5746']
DOI: https://doi.org/10.1161/svin.121.000188