Impact of one-layer assumption on diffuse reflectance spectroscopy of skin

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of one-layer assumption on diffuse reflectance spectroscopy of skin.

Diffuse reflectance spectroscopy (DRS) can be used to noninvasively measure skin properties. To extract skin properties from DRS spectra, you need a model that relates the reflectance to the tissue properties. Most models are based on the assumption that skin is homogenous. In reality, skin is composed of multiple layers, and the homogeneity assumption can lead to errors. In this study, we anal...

متن کامل

Quantitative Diffuse Reflectance Spectroscopy

In the field of biomedical optics, diffuse reflectance spectroscopy (DRS) is a frequently used technique for obtaining information about the optical properties of the medium under investigation. The method utilizes spectral difference between incident and backscattered light intensity for quantifying the underlying absorption and scattering processes that affects the light-medium interaction. I...

متن کامل

Diffuse Reflectance Spectroscopy

The appearance of a soil results from the interaction of its different constituents with incident light. Color and various other attributes of the appearance of soil are highly sensitive to the nature, proportion, particle size and morphology, and spatial association of its mineral and organic components. In fact, color has been used for more than 75 yr to obtain information about these soil pr...

متن کامل

Instrument independent diffuse reflectance spectroscopy.

Diffuse reflectance spectroscopy with a fiber optic probe is a powerful tool for quantitative tissue characterization and disease diagnosis. Significant systematic errors can arise in the measured reflectance spectra and thus in the derived tissue physiological and morphological parameters due to real-time instrument fluctuations. We demonstrate a novel fiber optic probe with real-time, self-ca...

متن کامل

the impact of training on second language writing assessment: a case of raters’ biasedness

چکیده هدف اول این تحقیق بررسی تأثیر آموزش مصحح بر آموزش گیرندگان براساس پایایی نمره های آنها در پنج بخش شامل محتوا ، سازمان ، لغت ، زبان و مکانیک بود. هدف دوم این بود که بدانیم آیا تفاوتهای بین آموزشی گیرندگان زن و مرد در پایایی نمرات آنها وجود دارد. برای بررسی این موارد ، ما 90 دانشجو در سطح میانه (متوسط) که از طریق تست تعیین سطح شده بودند انتخاب شدند. بعد از آنها خواستیم که درباره دو موضوع ا...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Biomedical Optics

سال: 2015

ISSN: 1083-3668

DOI: 10.1117/1.jbo.20.2.027001