منابع مشابه

Quantification of Carbon Dioxide Removal at Low Sweep Gas and Blood Flows.

Advancement in oxygenator membrane technology has further expanded the boundaries in the clinical application of extracorporeal carbon dioxide removal (ECCO2R). Despite the advent of modern poly-4-methyl-1-pentene (PMP) membranes, limited information exists on the performance of these membranes at low sweep gas and blood flows. Moreover, physiological relationships for CO2 removal at these flow...

متن کامل

Veno-venous extracorporeal CO2 removal for the treatment of severe respiratory acidosis: pathophysiological and technical considerations

INTRODUCTION While non-invasive ventilation aimed at avoiding intubation has become the modality of choice to treat mild to moderate acute respiratory acidosis, many severely acidotic patients (pH <7.20) still need intubation. Extracorporeal veno-venous CO2 removal (ECCO2R) could prove to be an alternative. The present animal study tested in a systematic fashion technical requirements for succe...

متن کامل

An extracorporeal carbon dioxide removal (ECCO2R) device operating at hemodialysis blood flow rates

BACKGROUND Extracorporeal carbon dioxide removal (ECCO2R) systems have gained clinical appeal as supplemental therapy in the treatment of acute and chronic respiratory injuries with low tidal volume or non-invasive ventilation. We have developed an ultra-low-flow ECCO2R device (ULFED) capable of operating at blood flows comparable to renal hemodialysis (250 mL/min). Comparable operating conditi...

متن کامل

Impact of membrane lung surface area and blood flow on extracorporeal CO2 removal during severe respiratory acidosis

BACKGROUND Veno-venous extracorporeal CO2 removal (vv-ECCO2R) is increasingly being used in the setting of acute respiratory failure. Blood flow rates through the device range from 200 ml/min to more than 1500 ml/min, and the membrane surface areas range from 0.35 to 1.3 m2. The present study in an animal model with similar CO2 production as an adult patient was aimed at determining the optimal...

متن کامل

Adverse effects of extracorporeal carbon dioxide removal (ECCO2R) for acute respiratory failure: a systematic review protocol

BACKGROUND The extracorporeal membrane carbon dioxide removal (ECCO2R) system is primarily designed for the purpose of removing CO2 from the body for patients with potentially reversible severe acute hypercapnic respiratory failure or being considered for lung transplantation. Systematic reviews have focused on the effectiveness of ECCO2R. To the author's best knowledge, this is the first syste...