Implantable cathodic voltage controlled electrical stimulator

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Implantable Foot Drop Stimulator

A novel partially implantable system for correction of foot drop has been developed and is being tested in three volunteer subjects. The system consists of a two-channel implantable stimulator, a multi-polar nerve cuff electrode implanted on the peroneal nerve proximal to the knee, and an external system including battery, control and telemetry unit and a heel switch. Although the work is still...

متن کامل

An implantable electrical stimulator used for peripheral nerve rehabilitation in rats

This study evaluated an implantable electrical stimulator using a sciatic nerve injury animal model, and ethological, electrophysiological and histological assessments. Forty Sprague-Dawley rats were used in the study, and were subjected to crushing of the right sciatic nerve with a micro-vessel clamp. Electrical stimulators were implanted in twenty of the rats (the implantation group), while t...

متن کامل

Design of a Implantable Selective Nerve Stimulator

At University College London implantable stimulators suitable for the selective stimulation of nerve are being developed. We hope these devices will be capable of selectively stimulating either by fibre position, fibre size or to launch action potentials in one direction only, using nerve cuff electrodes. These methods of selective stimulation have been demonstrated by many workers; early paper...

متن کامل

Improving Tenderness of Forage-Finished Beef Using a Low-Voltage Electrical Stimulator

What was done (summary) This study was designed to examine the effectiveness of low-voltage electrical stimulation (ES) in improving meat tenderness of forage-finished beef when used in a small-scale, low-volume slaughter plant. In experiment 1, the effect of ES on postmortem glycolysis was inves­ tigated by measuring metabolite concentrations in 10 cattle (5 ES and 5 control). ES accelerated p...

متن کامل

Design of Electrical Stimulator with High-Voltage-Tolerant Stimulus Driver in a 0.18μm Low-Voltage CMOS Process

This paper presents an electrical stimulator with four high-voltage-tolerant output channels for cochlear implant in a 0.18μm low-voltage CMOS process. As the maximum stimulation voltage can be as high as 7 V, this stimulator only needs one single supply voltage of 1.8 V. To implement this stimulator in a low-voltage CMOS process, the dynamic bias technique and stacked MOS configuration are use...