Implementing VIPER for Imaging Cellular Proteins by Fluorescence Microscopy
نویسندگان
چکیده
منابع مشابه
Probing subtle fluorescence dynamics in cellular proteins by streak camera based Fluorescence Lifetime Imaging Microscopy
We report the cell biological applications of a recently developed multiphoton fluorescence lifetime imaging microscopy system using a streak camera (StreakFLIM). The system was calibrated with standard fluorophore specimens and was shown to have high accuracy and reproducibility. We demonstrate the applicability of this instrument in living cells for measuring the effects of protein targeting ...
متن کاملImaging without fluorescence: nonlinear optical microscopy for quantitative cellular imaging.
Quantitative single-cell analysis enables the characterization of cellular systems with a level of detail that cannot be achieved with ensemble measurement. In this Feature we explore quantitative cellular imaging applications with nonlinear microscopy techniques. We first offer an introductory tutorial on nonlinear optical processes and then survey a range of techniques that have proven to be ...
متن کاملAorta Fluorescence Imaging by Using Confocal Microscopy
The activated leukocyte attacked the vascular endothelium and the associated increase in VEcadherin number was observed in experiments. The confocal microscopic system with a prism-based wavelength filter was used for multiwavelength fluorescence measurement. Multiwavelength fluorescence imaging based on the VEcadherin within the aorta segment of a rat was achieved. The confocal microscopic sys...
متن کاملSpectral imaging fluorescence microscopy.
The spectral resolution of fluorescence microscope images in living cells is achieved by using a confocal laser scanning microscope equipped with grating optics. This capability of temporal and spectral resolution is especially useful for detecting spectral changes of a fluorescent dye; for example, those associated with fluorescence resonance energy transfer (FRET). Using the spectral imaging ...
متن کاملFluorescence anisotropy imaging microscopy
We constructed an optical system and developed the software to create and analyze the fluorescence anisotropy images of a variety of objects including single molecules, quantum dots, proteins, nucleic acids and cells. The system includes an inverted microscope, three calcite prisms (CPs) inserted in the excitation and emission optical paths, and CCD camera. The system allows to record dynamic c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: BIO-PROTOCOL
سال: 2019
ISSN: 2331-8325
DOI: 10.21769/bioprotoc.3413