Improved Load Frequency Control Using a Fast Acting Active Disturbance Rejection Controller
نویسندگان
چکیده
منابع مشابه
Improved Load Frequency Control Using a Fast Acting Active Disturbance Rejection Controller
System frequency may change from defined values while transmitting power from one area to another in an interconnected power system due to various reasons such as load changes and faults. This frequency change causes a frequency error in the system. However, the system frequency should always be maintained close to the nominal value even in the presence of model uncertainties and physical const...
متن کاملPID controller with improved load-disturbance rejection
In this paper a two-degree-of-freedom (2DOF) IMC structure is considered for integrating process with deadtime to achieve improved load-disturbance response along with the set-point response. Set-point controller is designed considering desired speed of response of the closed-loop system. The load-disturbance controller is designed through direct synthesis approach and both the controllers are ...
متن کاملImproved Linear Active Disturbance Rejection Control for Microgrid Frequency Regulation
The frequency regulation has become one of the major subjects in microgrid power system due to the complexity structure of microgrid. In order to solve this problem, this paper proposes an improved linear active disturbance rejection control algorithm (ILADRC) that can significantly improve system performances through changing feedback control law to reduce the disturbance estimation error of e...
متن کاملApplication of Linear Active Disturbance Rejection Control to Power System Load Frequency Control
In this paper, linear active disturbance rejection control (LADRC) is employed to deal with the load frequency control (LFC) problem in power systems with a single generator supplying power to a single service area. First, the general (n+1)th order LADRC is given, and then the parameter tuning procedures are presented. It is followed by the description of an LFC problem, in which the case of a ...
متن کاملVoltage Control of Three Phase Inverters by Using Active Disturbance Rejection Control
Control of three phase inverters has been an important issue in recent years. This paper proposes active disturbance rejection control (ADRC) scheme for controlling three phase inverters. The main advantage of ADRC that motivated us for using this controller for inverter is that it is model independent. This controller is used in a double loop structure including an inner current loop and oute...