Improved Load Frequency Control Using a Fast Acting Active Disturbance Rejection Controller

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Load Frequency Control Using a Fast Acting Active Disturbance Rejection Controller

System frequency may change from defined values while transmitting power from one area to another in an interconnected power system due to various reasons such as load changes and faults. This frequency change causes a frequency error in the system. However, the system frequency should always be maintained close to the nominal value even in the presence of model uncertainties and physical const...

متن کامل

PID controller with improved load-disturbance rejection

In this paper a two-degree-of-freedom (2DOF) IMC structure is considered for integrating process with deadtime to achieve improved load-disturbance response along with the set-point response. Set-point controller is designed considering desired speed of response of the closed-loop system. The load-disturbance controller is designed through direct synthesis approach and both the controllers are ...

متن کامل

Improved Linear Active Disturbance Rejection Control for Microgrid Frequency Regulation

The frequency regulation has become one of the major subjects in microgrid power system due to the complexity structure of microgrid. In order to solve this problem, this paper proposes an improved linear active disturbance rejection control algorithm (ILADRC) that can significantly improve system performances through changing feedback control law to reduce the disturbance estimation error of e...

متن کامل

Application of Linear Active Disturbance Rejection Control to Power System Load Frequency Control

In this paper, linear active disturbance rejection control (LADRC) is employed to deal with the load frequency control (LFC) problem in power systems with a single generator supplying power to a single service area. First, the general (n+1)th order LADRC is given, and then the parameter tuning procedures are presented. It is followed by the description of an LFC problem, in which the case of a ...

متن کامل

Voltage Control of Three Phase Inverters by Using Active Disturbance Rejection Control

Control of three phase inverters has been an important issue in recent years. This paper proposes active disturbance rejection control (ADRC) scheme for controlling three phase inverters. The main advantage of ADRC that motivated us for using this controller for inverter is that it is model independent.  This controller is used in a double loop structure including an inner current loop and oute...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2017

ISSN: 1996-1073

DOI: 10.3390/en10111718