Improved motion correction for T1 mapping
نویسندگان
چکیده
منابع مشابه
Improved motion correction for T1 mapping
Medicine, BIDMC/Harvard Medical School, Boston, Massachusetts, USA Full list of author information is available at the end of the article Figure 1 DICE similarity coefficients obtained with and without the proposed motion correction approach in pre (5-3 scheme) and post contrast (4-3-2 scheme) T1w image series. Average DICE coefficients over each T1w image series (left column), and over each in...
متن کاملMyocardial T1 Mapping with Synthetic Image Estimation based Motion Correction
H. Xue, S. Shah, A. Greiser, C. Guetter, C. Chefdhotel, M-P. Jolly, S. Zuehlsdorff, J. Guehring, and P. Kellman Imaging and Visualization, Siemens Corporate Research, Princeton, NJ, United States, CMR Research and Development, Siemens Medical Solutions USA, Inc., Chicago, IL, United States, Imaging & IT Division, Siemens AG, Healthcare Sector, Erlangen, Germany, National Heart, Lung and Blood I...
متن کاملImproved motion correction using image registration based on variational synthetic image estimation: application to inline t1 mapping of myocardium
Introduction Myocardial T1 mapping has potential to quantify structural and pathological changes without use of contrast agent. Recently Modified Look-Locker Inversion Recovery (MOLLI) sequence has proven effective on cardiac T1 mapping [1]. Its clinical applicability is still limited by myocardial motion between frames mainly due to beat to beat variations and respiration. This undesired motio...
متن کاملMotion correction for myocardial T1 mapping using image registration with synthetic image estimation.
Quantification of myocardial T1 relaxation has potential value in the diagnosis of both ischemic and nonischemic cardiomyopathies. Image acquisition using the modified Look-Locker inversion recovery technique is clinically feasible for T1 mapping. However, respiratory motion limits its applicability and degrades the accuracy of T1 estimation. The robust registration of acquired inversion recove...
متن کاملMyocardial T1 Mapping with Phase-Sensitive Motion Correction and Inversion Recovery Fitting
Hui Xue, Andreas Greiser, Christoph Guetter, Sven Zuehlsdorff, Marie-Pierre Jolly, Andrew E. Arai, Jens Guehring, and Peter Kellman Siemens Corporate Research, Princeton, New Jersey, United States, Imaging & IT Division, Siemens AG, Healthcare Sector, Erlangen, Germany, CMR R&D, Siemens Medical Solutions USA, Inc., Chicago, IL, United States, Laboratory of Cardiac Energetics, National Institute...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance
سال: 2014
ISSN: 1532-429X
DOI: 10.1186/1532-429x-16-s1-p45