Improved MR thermometry for laser interstitial thermotherapy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Temperature Rise and Thermal Lesion Dimensions in Liver Laser Interstitial Thermotherapy

Introduction:  Laser  interstitial  thermotherapy  (LITT)  is  an  internal  ablation  therapy  method  consisting of a percutaneous or intraoperative insertion of laser fibers directly into the liver tumor with  maximum diameter of 5 cm. In this treatment method, there isn’t any general information about the  relationship  between  increasing  the  exposure  power,  coagulation  and  carboniza...

متن کامل

MRI thermometry in phantoms by use of the proton resonance frequency shift method: application to interstitial laser thermotherapy.

In this work the temperature dependence of the proton resonance frequency was assessed in agarose gel with a high melting temperature (95 degrees C) and in porcine liver in vitro at temperatures relevant to thermotherapy (25-80 degrees C). Furthermore, an optically tissue-like agarose gel phantom was developed and evaluated for use in MRI. The phantom was used to visualize temperature distribut...

متن کامل

MR-guided laser induced thermotherapy (LITT) of liver metastases

Purpose To demonstrate clinical findings and imaging criteria of side-effects and complications immediatly and delayed after the MR-guided LITT for the treatment of liver metastases. Material and methods In a time frame of 6 years 411 patients were prospectively treated with MR-guided LITT for liver metastases. Between June 1993 and March 1999 a total of 2440 laser applications were performed t...

متن کامل

Transurethral prostate thermotherapy: filtering the bowel motion during MR-thermometry processing

Background/introduction Magnetic resonance imaging (MRI)-guided transurethral ultrasound therapy is a minimally-invasive image-guided treatment for localized prostate cancer offering precise targeting of tissue within the gland. The accuracy of MR thermometry is critical for precise on-line feedback control as well as for monitoring potential thermal injury of surrounding tissues, especially th...

متن کامل

SSFP-based MR thermometry.

Of the various techniques employed to quantify temperature changes by MR, proton resonance frequency (PRF) shift-based phase-difference imaging (PDI) is the most accurate and widely used. However, PDI is associated with various artifacts. Motivated by these limitations, we developed a new method to monitor temperature changes by MRI using the balanced steady-state free precession (balanced-SSFP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Lasers in Surgery and Medicine

سال: 2019

ISSN: 0196-8092,1096-9101

DOI: 10.1002/lsm.23049