Improved sensitivity for two-photon frequency-domain lifetime measurement.
We demonstrate a method to improve the measurement sensitivity of two-photon frequency-domain lifetime measurements in poor signal to background conditions. This technique uses sinusoidal modulation of the two-photon excitation source and detection of the second harmonic of the modulation frequency that appears in the emission. Additionally, we present the mathematical model which describes how...
متن کاملInnovative Methodology Photon counting, censor corrections, and lifetime imaging for improved detection in two-photon microscopy
Jonathan D. Driscoll, Andy Y. Shih, Satish Iyengar, Jeffrey J. Field, G. Allen White, Jeffrey A. Squier, Gert Cauwenberghs, and David Kleinfeld Department of Physics, University of California at San Diego, La Jolla, California; Department of Statistics, University of Pittsburgh, Pittsburgh, Pennsylvania; Department of Physics, Colorado School of Mines, Golden, Colorado; and Department of Bioeng...
متن کاملPhoton counting, censor corrections, and lifetime imaging for improved detection in two-photon microscopy.
We present a high-speed photon counter for use with two-photon microscopy. Counting pulses of photocurrent, as opposed to analog integration, maximizes the signal-to-noise ratio so long as the uncertainty in the count does not exceed the gain-noise of the photodetector. Our system extends this improvement through an estimate of the count that corrects for the censored period after detection of ...
متن کاملIterative correction for ‘pile-up’ in single-photon lifetime measurement
A novel iterative algorithm is proposed to correct for pulse, or photon, ‘pile-up’ in the measurement of temporal intensity profiles using time-correlated single-photon counting (TCSPC). Despite the existence of correction algorithms since 1968, most TCSPC experiments are operated in a very low photon-count mode to avoid pulse pile-up effects in the data. This is inefficient and time-consuming,...
متن کاملPhoton counting , censor corrections , and lifetime imaging for 1 improved detection in two - photon microscopy 2 3
3 Jonathan D. Driscoll, Andy Y. Shih, Satish Iyengar, Jeffrey J. Field, 4 G. Allen White, Jeffrey A. Squier, Gert Cauwenberghs and David Kleinfeld 5 6 Department of Physics, University of California at San Diego, La Jolla, CA 7 Department of Statistics, University of Pittsburgh, Pittsburgh, PA 8 Department of Physics, Colorado School of Mines, Golden, CO 9 Department of Bioengineering, Universi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2010
ISSN: 1094-4087
DOI: 10.1364/oe.18.013631