Improvement in systematic error in background-oriented schlieren results by using dynamic backgrounds

نویسندگان

چکیده

Abstract The use of electronic visual displays for background-oriented schlieren allows the quick change reference images. In this study, we show that quality synthetic and images can be improved by acquiring a set with different generating median displacement field from it. To explore potential benefits, studied background changing strategies their effect on evaluation via artificial experimental image distortions. Graphic abstract

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Density measurements using the Background Oriented Schlieren technique

This paper describes the implementation of a novel technique called Background Oriented Schlieren that can produce quantitative visualization of density in a flow. This technique uses only a digital still camera, a structured background, and inverse tomographic algorithms which can extract two-dimensional slices from a three-dimensional flow. This has been applied to obtain the density field fo...

متن کامل

Assessment and application of quantitative schlieren methods: Calibrated color schlieren and background oriented schlieren

Two quantitative schlieren methods are assessed and compared: calibrated color schlieren (CCS) and background oriented schlieren (BOS). Both methods are capable of measuring the light deflection angle in two spatial directions, and hence the projected density gradient vector field. Spatial integration using the conjugate gradient method returns the projected density field. To assess the perform...

متن کامل

Background rejection in schlieren visualization

Schlieren visualization is one of the simplest ways of determining the geometric parameters of an ultrasonic beam generated by diagnostic transducers, and is recommended for evaluating the potential and the limitations of ultrasonic equipment used in diagnostic applications.’ Apart from some special cases, for example, dynamically focused and/or scanned receiving arrays, the shape of the transm...

متن کامل

Background-oriented schlieren imaging and tomography for rapid measurement of FUS pressure fields: initial results

Background/introduction FUS pressure field mapping is important for dosimetry, quality assurance, and other uses. Hydrophone measurements are the current standard, and are accurate but costly and slow. As a simple low-cost alternative, background-oriented schlieren (BOS) imaging of ultrasound fields has been proposed.[1] In that technique, a predetermined image (usually a grid of lines or a ran...

متن کامل

Non-Intrusive measurement of a density field using the Background Oriented Schlieren(BOS) method

A method is described for measuring the density distribution in an inhomogeneous medium. This method is based upon the classical Schlieren technique, known as Background Oriented Schlieren (BOS) method. The method measures the density dependence of the refractivity through the detection of the deflecting angle of a number of light beams passing through the space to be measured. The results of s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Experiments in Fluids

سال: 2021

ISSN: ['0723-4864', '1432-1114']

DOI: https://doi.org/10.1007/s00348-021-03285-6