Improving FEM crash simulation accuracy through local thickness estimation based on CAD data
نویسندگان
چکیده
منابع مشابه
Improving FEM crash simulation accuracy through local thickness estimation based on CAD data
In this paper, we present a method for estimating local thickness distribution in finite element models, applied to injection molded and cast engineering parts. This method features considerable improved performance compared to two previously proposed approaches, and has been validated against thickness measured by different human operators. We also demonstrate that the use of this method for a...
متن کاملMicrosystem CAD: From FEM to System Simulation
Microsystem technology is a highly interdisciplinary area. Therefore, a combination of different CAD methods and tools is necessary for supporting microsystem design. Process and device simulation are basic CAD methods but more and more higher levels of abstraction need to be applied in order to analyze microsystems adequately. This paper summarizes several modeling and simulation strategies fo...
متن کاملData Mining on Crash Simulation Data
The work presented in this paper is part of the cooperative research project AUTO–OPT carried out by twelve partners from the automotive industries. One major work package concerns the application of data mining methods in the area of automotive design. Suitable methods for data preparation and data analysis are developed. The objective of the work is the re–use of data stored in the crash–simu...
متن کاملconstructing gender identity through narratives based on hallidays metafunctions
هویت, شکل دادن و بازنمایی آن در گفتمان, توجه بسیاری از محققان این رشته را به خود جلب کرده است. تحقیق حاضر بر شکل دادن به هویت جنسیتی هشت تن از دانشجویان ایرانی مشغول به تحصیل در دوره کارشناسی ارشد از طریق بررسی روایات آنان از تجربیات شخصی, متمرکز شده است. تحلیل داده ها در این تحقیق مشتمل بر سه بخش است: بخش اول شامل کدگذاری موضوعی روایات است که بر اساس آن هویت جنسیتی شرکت کنندگان در تحقیق بر اسا...
15 صفحه اولThorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Engineering Software
سال: 2014
ISSN: 0965-9978
DOI: 10.1016/j.advengsoft.2014.02.003