Effect of Voltage on Radiation Characteristics of Triggered Vacuum Diode
Based on the conduction mechanism of vacuum trigger diode, an experimental scheme has been designed to research on the effect of voltage parameters on radiation characteristics of vacuum trigger diode. The factors, including charging voltage and anode-cathode voltage, affecting radiation characteristics of vacuum trigger diode are analyzed. Through measure and analysis of trigger current, the r...
متن کاملIncreased surface flashover voltage in microfabricated devices
This document is made available in accordance with publisher policies and may differ from the published version or from the version of record. If you wish to cite this item you are advised to consult the publisher's version. Please see the URL above for details on accessing the published version. Copyright and all moral rights to the version of the paper presented here belong to the individual ...
متن کاملEvaluation of network performance for triggering using a large switch
This paper describes measurements made to evaluate the performance of networks carrying the traffic expected for the second level trigger of the ATLAS experiment [1] at the Large Hadron Collider. As the network technology used here [2] is not the technology that will appear in the final system, we have termed the process emulation. The results obtained are part of the programme to determine the...
متن کاملInitiation Mechanism of Pulsed Surface Flashover along Silicon in Vacuum by Pre-breakdown Conduction and Photon Emission
Pre-breakdown (leakage) and breakdown currents and photon-emission associated with the currents, under impulse (0.36!10 IJ-S) voltage stress, along high purity (p>30 KQ em) silicon, with and without gold end contacts in vacuum (-lQ-6 Torr), are discussed. Three distinct phases leading to the breakdown condition are observed. These are one-carrier (hole) leakage current, two-carrier (electrons a...
متن کاملComparison of triggering systems for neonatal patient triggered ventilation.
The efficacy of two triggering systems was compared during neonatal patient triggered ventilation: the Graseby MR10 respiration monitor and airway pressure changes. Ten preterm infants were studied, median gestational age 33 weeks (range 28-35). Patient triggered ventilation was administered via the SLE ventilator at a series of inflation times (0.24, 0.3, and 0.4 seconds). Comparison was made ...