In reply: Comparing videolaryngoscope and direct laryngoscope use for nasotracheal intubation in patients with manual in-line stabilization
نویسندگان
چکیده
منابع مشابه
Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope.
BACKGROUND The GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over the Macintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether ther...
متن کاملManual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation.
BACKGROUND Manual in-line stabilization (MILS) is recommended during direct laryngoscopy and intubation in patients with known or suspected cervical spine instability. Because MILS impairs glottic visualization, the authors hypothesized that anesthesiologists would apply greater pressure during intubations with MILS than without. METHODS Nine anesthetized and pharmacologically paralyzed patie...
متن کاملPentax-AWS videolaryngoscope for nasotracheal intubation in patients with difficult airways
Corresponding author: Keon-Sik Kim, M.D., Department of Anesthesiology and Pain Medicine, Kyung Hee University Medical Center, Hoegidong, Dongdaemun-gu, Seoul 130-702, Korea. Tel: 82-2-958-8591, Fax: 82-2-958-8580, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http:// creativecommons.org/license...
متن کاملPentax-AWS videolaryngoscope for awake nasotracheal intubation in patients with a difficult airway.
متن کامل
hemodynamic changes following endotracheal intubation in patients undergoing cesarean section with general anesthesia: application of glidescope® videolaryngoscope versus direct laryngoscope
objectives the aim of this study was to compare hemodynamic changes following endotracheal intubation with gvl and mdl in patients undergoing cesarean section by general anesthesia. materials and methods seventy patients undergoing elective cesarean section by general anesthesia requiring endotracheal intubation were randomly allocated to be intubated with either gvl (n = 35) or mdl (n = 35). s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Journal of Anesthesia/Journal canadien d'anesthésie
سال: 2019
ISSN: 0832-610X,1496-8975
DOI: 10.1007/s12630-019-01462-0