In Silico Contact Pressure of Metal-on-Metal Total Hip Implant with Different Materials Subjected to Gait Loading

نویسندگان

چکیده

The use of material for implant bearing has a vital role in minimizing failures that endanger recipients. Evaluation contact pressure can be the basis selection and have correlations with wear contribute to need revision operations. current paper aims investigate three different metallic materials, namely cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), titanium alloy (Ti6Al4V) application metal-on-metal total hip terms pressure. In silico model based on finite element simulation been considered predict bearings under normal walking conditions. It is found Ti6Al-4V-on-Ti6Al4V superior its ability reduce by more than 35% compared other studied couple bearings.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip resurfacing versus metal-on-metal total hip arthroplasty - are metal ion levels different?

A systematic review and meta-analysis of trials comparing hip resurfacing to metal-on-metal total hip arthroplasty was conducted to determine if there is a difference in serum metal ion levels in patients receiving these implants. EMBASE and MEDLINE databases were searched from inception to December 2010 for all trials involving the use of these devices. Eligibility for inclusion in the review ...

متن کامل

Contact mechanics of modular metal-on-polyethylene total hip replacement under adverse edge loading conditions

Edge loading can negatively impact the biomechanics and long-term performance of hip replacements. Although edge loading has been widely investigated for hard-on-hard articulations, limited work has been conducted for hard-on-soft combinations. The aim of the present study was to investigate edge loading and its effect on the contact mechanics of a modular metal-on-polyethylene (MoP) total hip ...

متن کامل

Painful metal-on-metal total hip arthroplasty.

Two patients were evaluated for the possibility of hypersensitivity to a Metasul articulation (Centerpulse, Austin, Tex) coupled with total hip arthroplasty. Serum was tested with a lymphocyte proliferation assay, and the capsular tissues from the hip were examined for perivascular lymphocytes. The diagnosis of hypersensitivity to Metasul could not be confirmed in these patients, and ultimately...

متن کامل

Asymmetrical hip loading correlates with metal ion levels in patients with metal-on-metal hip resurfacing during sit-to-stand.

The occurrence of pseudotumours following metal-on-metal hip resurfacing arthroplasty (MoMHRA) has been associated with high serum metal ion levels and consequently higher than normal bearing wear. Measuring ground reaction force is a simple method of collecting information on joint loading during a sit-to-stand (STS). We investigated vertical ground reaction force (VGRF) asymmetry during sit-t...

متن کامل

Metal Hypersensitivity to Implant Materials

Hypersensitivity to TMJ implant materials is an issue that we are frequently hearing from TMJ patients. Given this concern we contacted Marco Caicedo, Ph.D., Senior Scientists and COO at Orthopedic Analysis in Chicago, IL. Orthopedic Analysis is an independent diagnostics company dedicated to the quantitative analysis of immune responses to biomaterials (i.e metal allergy to implant materials)....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Metals

سال: 2022

ISSN: ['2075-4701']

DOI: https://doi.org/10.3390/met12081241