Incremental Dynamic Analysis for Estimating Seismic Performance of Multi-Story Buildings with Butterfly-Shaped Structural Dampers
نویسندگان
چکیده
منابع مشابه
Seismic Design of Multi-story Buildings with Metallic Structural Fuses
Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for repairs. An alternative design approach is to concentrate damage on disposable and easy to repair structural elements (i.e., “structural fuses”), while the main structure is des...
متن کاملEvaluation of Seismic Performance of Combined Horizontal and Vertical Hexagrid Structural System for High-rise Buildings
Summary In this study, the seismic performance of hexagrid structures which are composed of horizontal and vertical hexagrid by using a transitional story, has been investigated. To this end, 10 models of 50-story hexagrid structures were designed. 9 models with horizontal hexagrid cells which transited to vertical cells using a transitional story, and a model of completely horizontal hexagrid ...
متن کاملExploring the Efficiency of Dampers for Repair and Strengthening of Existing Buildings
In this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. Seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. The finite element modeling technique (SAP2000 Software) is used for analysis. Time History analyzing was done to achieve this purpose. For nonlinear dynamic analysis, the responses of ...
متن کاملStructural Magnetic Induction Dampers in Buildings
This thesis discusses the feasibility of structural magnetic induction dampers for dampening mechanical vibrations in buildings subjected to strong dynamic excitations. The concept of energy harvesting in various fields of engineering is first examined. Then it is applied to the design of magnetic induction dampers in buildings. Various implementations of these dampers are proposed and the rela...
متن کاملSeismic Performance of Torsionally Stiff and Flexible Single Story Buildings Designed Based on Iranian Seismic Code(Standard 2800)
This paper examines differences in performances of a range of torsionally stiff and flexible single story buildings designed with the provisions of Iranian Standard 2800. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi-directional design spectra compatible ground motions are investigated. These models cover a wide range of very torsional...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2019
ISSN: 2075-5309
DOI: 10.3390/buildings9040078