Indirect absorption spectroscopy using quantum cascade lasers: mid-infrared refractometry and photothermal spectroscopy

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cavity ringdown spectroscopy using mid-infrared quantum-cascade lasers.

Cavity ringdown spectra of ammonia at 10 parts in 10(9) by volume (ppbv) and higher concentrations were recorded by use of a 16-mW continuous-wave quantum-casacde distributed-feedback laser at 8.5 mum whose wavelength was continuously temperature tuned over 15 nm. A sensitivity (noise-equivalent absorbance) of 3.4x10(-9) cm(-1) Hz(-1/2) was achieved for ammonia in nitrogen at standard temperatu...

متن کامل

Quantum Cascade Lasers Enhance Mid-IR Spectroscopy

Most vapor molecules have a unique absorption spectrum in the mid-IR region, so this range is of particular interest for trace gas analysis and chemical sensing. And quantum cascade (QC) lasers are ideal candidate light sources for mid-IR spectroscopy: Their emission wavelength reaches from the midto the far-IR with good power efficiency. QC lasers are based on the intersubband transitions betw...

متن کامل

Mid-infrared photothermal heterodyne spectroscopy in a liquid crystal using a quantum cascade laser.

We report a technique to measure the mid-infrared photothermal response induced by a tunable quantum cascade laser in the neat liquid crystal 4-octyl-4'-cyanobiphenyl (8CB), without any intercalated dye. Heterodyne detection using a Ti:sapphire laser of the response in the solid, smectic, nematic and isotropic liquid crystal phases allows direct detection of a weak mid-infrared normal mode abso...

متن کامل

Infrared absorption nano-spectroscopy using sample photoexpansion induced by tunable quantum cascade lasers.

We report a simple technique that allows obtaining mid-infrared absorption spectra with nanoscale spatial resolution under low-power illumination from tunable quantum cascade lasers. Light absorption is detected by measuring associated sample thermal expansion with an atomic force microscope. To detect minute thermal expansion we tune the repetition frequency of laser pulses in resonance with t...

متن کامل

Photoacoustic spectroscopy using quantum-cascade lasers.

Photoacoustic spectra of ammonia and water vapor were recorded by use of a continuous-wave quantum-cascade distributed-feedback (QC-DFB) laser at 8.5 mum with a 16-mW power output. The gases were flowed through a cell that was resonant at 1.6 kHz, and the QC-DFB source was temperature tuned over 35 nm for generation of spectra or was temperature stabilized on an absorption feature peak to permi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2013

ISSN: 1094-4087

DOI: 10.1364/oe.21.025643