Indirect estimation of overhead line ampacity in overhead lines integrating wind farms

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Real-time position estimation of overhead line in railway application

In this paper we describe a new method to measure the position of an overhead line in a railway application. The height and stagger of an overhead line can nowadays be measured through a stereo-vision system composed of two line scanner cameras; the existing applications, unfortunately, cause some malfunctioning. In this work we want to test a new method that increases the resolution of wire im...

متن کامل

Mechanical Design of Overhead Lines

8.17 Some Mechanical Principles Introduction Electric power can be transmitted or dis tributed either by means of underground cables or by overhead lines. The underground* cables are rarely used for power transmission due to two main reasons. Firstly, power is generally transmitted over long distances to load centres. Obviously, the installation costs for underground transmission will be very h...

متن کامل

Lightning Protection of Overhead Power Distribution Lines

Distribution lines are often located in areas with high ground flash densities, being therefore subject to lightning-caused power interruptions. This paper presents an overview of the various types of lightning overvoltages that can arise on overhead power distribution networks, as well as typical voltage waveforms. The effectivenesses of the most important methods for mitigating such overvolta...

متن کامل

Power transmission capacity upgrade of overhead lines

Electric power consumption, has been increasing uninterruptedly, being this increase specially accelerated in the last years. New power generators are been built, the installed power increases each year, thus it is necessary a way to transmit the bulk energy. Nowadays electric lines are saturated, they are reaching critical values of ampacity and sag. Therefore building new lines is necessary t...

متن کامل

Lightning-induced Overvoltages in Overhead Power Distribution Lines: Importance of the Line Grounding Electrodes Modeling

Models for the calculation of lightning-induced voltages on distribution networks, should be able to take into account the presence of shielding wires and/or neutral conductors and of their relevant groundings. The paper deals with the estimation of the influence of these groundings with particular reference to the grounding electrode model on the calculated values of the lightninginduced volta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Renewable Energy and Power Quality Journal

سال: 2014

ISSN: 2172-038X,2172-038X

DOI: 10.24084/repqj12.253