Inductively coupled plasma optical emission spectrometry with axially viewed configuration: an overview of applications
نویسندگان
چکیده
منابع مشابه
Inductively Coupled Plasma - Optical Emission Spectrometry
ACKNOWLEDGEMENTS INTRODUCTION CONTENTS 1.1 Forensic Science Investigations 1.2 Forensic Science Analysis 2 1.3 Inductively Coupled Plasma-Optical Emission Spectrometry 7 1.4 The Aims of This Investigation 8 2 INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY 10 2 .l Introduction 2.2 The Inductively Coupled Plasma 2.3 Instrumentation Used in This Study 2.3.1 Radio Frequency Generator 2.3....
متن کاملMicrowave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes
Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...
متن کاملMarine Sediment Analysis Using Inductively Coupled Plasma Optical Emission Spectrometry
Inductively coupled plasma optical emission spectrometry was applied to the determination of trace impurities in tantalum powder. The matrix effects of tantalum in the determination of trace level impurities such as Cr, Fe, Nb, Ni, and Ti were studied by measuring the intensities of each trace element in solution at various concentrations of tantalum. As the concentration of the interfering ele...
متن کاملMatrix effects on the determination of dysprosium, europium and ytterbium used as animal faecal markers by inductively coupled plasma optical emission spectrometry with axially- and radially- viewed configurations
Matrix effects were evaluated on the determination of Dy, Eu and Yb used as sheep faecal markers by inductively coupled plasma optical emission spectrometry (ICP-OES) with axiallyand radially-viewed configurations. The samples were prepared with microwave-assisted acid digestion using an oven with closed vessels. The analytical performances of the two ICP-OES instruments were compared using Mg ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Brazilian Chemical Society
سال: 2007
ISSN: 0103-5053
DOI: 10.1590/s0103-50532007000400003