Influence of Location and Capacity of Distributed Generations on Voltage Sags Mitigation Using Alternative Transient Program
نویسندگان
چکیده
منابع مشابه
Mitigation of Voltage Sags/swells Using Dynamic Voltage Restorer (dvr)
This paper describes the effectiveness of using dynamic voltage restorer (DVR) in order to mitigate voltage sags and swells in low voltage distribution systems. A dynamic voltage restorer based on the dqo algorithm is discussed. The proposed control scheme is very effective to detect any disturbance in low voltage distribution systems. Simulation results using Matlab/Simulink are presented to v...
متن کاملDetermination of Optimal Capacity and Location of Distributed Generations in Radial Distribution Systems using Krill Herd Algorithm
Abstract Reliability and active power loss are two fundamental parameters in the design and planning of distribution systems that have always attracted the attention of power distribution systems designers and engineers. The improvement of reliability and the reduction of power loss are investigated as the primary objective functions and voltage profile as the secondary objective function. A me...
متن کاملdegradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses
در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...
15 صفحه اولMitigation Of Voltage Sags/Swells By Dynamic Voltage Restorer Using Pi And Fuzzy Logic Controller
Dynamic Voltage Restorer can provide the most cost effective solution to mitigate voltage sags and swells by establishing the proper voltage quality level that is required by customer. This device is connected in series with the distribution feeder at medium voltage. The PI controller is very common in the control of DVRs. However, one disadvantage of this conventional controller is the fact th...
متن کاملA Simple Method for Detection of Voltage Sags and their Mitigation using a Dynamic Voltage Restorer
Power quality is the major focus of progressive nations.In the era of smart grid,power quality receives a lot of thrust at all voltage levels namely,medium ,high and low.The objective of this paper is to present a simple and cost effective method of sag detection and mitigation in three phase systems at the consumer's end. The use of the concept of space vector representation of three phase qua...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IOP Conference Series: Materials Science and Engineering
سال: 2020
ISSN: 1757-899X
DOI: 10.1088/1757-899x/1003/1/012140