Inspired Oxygen Concentrations with or without an Oxygen Economizer during Ether Draw-Over Anaesthesia

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Domiciliary oxygen concentrators in anaesthesia: preoxygenation techniques and inspired oxygen concentrations.

A conventional preoxygenation technique was compared in two volunteers with two techniques based on a drawover breathing system supplied with oxygen enriched air from a Devilbiss Mini VO2 domiciliary oxygen concentrator. Breathing from a 20-litre bag, filled previously at 2 litre min-1 from the concentrator was as effective as the conventional technique (PaO2 73.2 kPa). Supplying 4 litre min-1 ...

متن کامل

Relationships between inspired oxygen concentration and venous admixture during nitrous oxide-oxygen-halothane anaesthesia.

The inspired oxygen concentration (F/O2) was changed on 43 occasions at about 30-min intervals in 13 patients during artificial ventilation with mixtures of nitrous oxide (N2O), oxygen and halothane. Ventilator settings remained unchanged for each patient and at the end of each period, samples of arterial and central venous blood (and, in six patients, pulmonary arterial blood) and inspired and...

متن کامل

Fuzzy logic control of inspired isoflurane and oxygen concentrations using minimal flow anaesthesia.

In order to evaluate the performance of feedback fuzzy logic control of inspired oxygen and isoflurane concentrations, we studied 30 patients undergoing discectomy for lumbar (n = 26) or cervical (n = 4) disc herniation. Patients were allocated random to one of two groups: a standard group (n = 15) with low flow anaesthesia (1.2-1.3 litre min-1) and manual control of gas concentrations; and a f...

متن کامل

Inspired oxygen concentrations in semiclosed circle absorber circuits with low flows of nitrous oxide and oxygen.

Fresh gas flows of 1-5 l./min containing oxygen concentrations of 25-50% in nitrous oxide were led into a semiclosed circle absorber circuit. The resulting inspired oxygen concentrations were measured under conditions of spontaneous respiration. The lower the fresh gas flow, the greater was the discrepancy between fresh gas and inspired oxygen concentration. No association between minute volume...

متن کامل

Inadvertent administration of 100% oxygen during anaesthesia.

Sir,—Modern anaesthetic machines have a device (usually referred to as "the oxygen bypass" or "emergency oxygen") which enables the anaesthetist to administer high flows of 100% oxygen. When a patient is connected to an anaesthetic machine it is possible to overlook the fact that the emergency oxygen device is in the "on" position and is delivering 100% oxygen. This occurrence is most likely if...