Instantaneous Shutters
نویسندگان
چکیده
منابع مشابه
Electro-optic Shutters and Filters
The psychologist and the visual scientist often need a rapid and silent means of interrupting or attenuating light. By using fluorescent lamps, glow-modulator tubes, light-emitting diodes, electroluminescent panels or cathode-ray tubes, it is sometimes feasible to modulate the light source : but often, because the light must be very intense or because particular spectral bands are required or b...
متن کاملSynchrotron Mössbauer spectroscopy using high-speed shutters
A new method of performing Mössbauer spectroscopy with synchrotron radiation is demonstrated that involves using a high-speed periodic shutter near the focal spot of a microfocused X-ray beam. This fast microshuttering technique operates without a high-resolution monochromator and has the potential to produce much higher signal rates. It also offers orders of magnitude more suppression of unwan...
متن کاملNote: fast, small, and low vibration mechanical laser shutters.
We present three novel mechanical laser shutter designs based, respectively, on a stepper motor, a relay, and a piezoelectric actuator. Each shutter type is ideally suited to a specific shuttering application. The stepper motor is well suited for applications requiring low vibrations, the relay is compact and capable of rapid bursts, and the piezoelectric is 2 orders of magnitude faster than ot...
متن کاملInstantaneous Gratification
Extending Barro (1999) and Luttmer & Mariotti (2003), we introduce a new model of time preferences: the instantaneous-gratification model. This model applies tractably to a much wider range of settings than existing models. It applies to complete and incomplete-market settings and it works with generic utility functions. It works in settings with linear policy rules and in settings in which equ...
متن کاملStability and Accuracy of HRC and WFC Shutters
Calibration observations (9662) have been used to quantify precise exposure time values, stability and shading effects down to the shortest allowed exposures (0.1s HRC, 0.5s WFC). A few of the shortest exposure times differ by up to 4% from nominal values, and we recommend for these cases that CALACS, or its reference files be changed to use the measured exposure times. In general no significan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature
سال: 1887
ISSN: 0028-0836,1476-4687
DOI: 10.1038/035366b0